Planning the Installation
Cabinet Layout
All maximum and minimum dimensions and clearances shown in the diagrams below must be maintained for safe operation.
Check the location where the range is to be installed. It should be placed away from drafts that may be caused by doors, windows
and heating and air conditioning outlets.
To reduce the risk of fire or personal injury from reaching over a hot appliance, avoid cabinet installations directly above the range.
If cabinet storage is to be provided, the risk can be reduced by installing a range hood that projects horizontally a minimum of 5
inches beyond the bottom of the cabinets.
The range may be installed flush to the rear wall. Dacor strongly recommends installing a non-combustible material on the rear
wall above the range and up to the vent hood or installation of a backguard. It is not necessary to install non-combustible materials
behind the range below the countertop height. Any openings in the wall behind the appliance or in the floor underneath it must be
sealed.
DIMENSIONS
Range Model F G H I J
RNRP36G
42” (106.2 cm)*
36” (91.4 cm)**
36”
(91.4 cm)**
33 1/2”
(84.8 cm)
30 7/8”
(78.4 cm)
3 1/2”
(8.9 cm)
RNRP48G
54” (137.2 cm)*
48” (121.9 cm)**
48”
(121.9 cm)**
43 1/2”
(110.2 cm)
29 7/8”
(75.9 cm)
3”
(7.6 cm)
* Recommended ** Minimum
Note 2
F
G
2
Cabinet/countertop depth is at discretion of customer but
cabinet face MUST NOT protrude further than rear of front
panel, see product dimensions.
3
Consult local code for exact location requirements.
1
Vertical from range grate level to combustible overhead
surface; if installing an overhead vent hood, also check
hood specifications for minimum required clearances.
4
Vertical from grate level to combustible surface.
Non-combustible
surface along back wall
recommended
10” (25.4 cm) min.
to combustible side
walls above the range
(both sides)
30” (76.2 cm)
min.
1
37 1/2”
(95.3 cm)
max.
13” (33.0 cm)
max.
5
15” (38.1 cm)
min.
4, 5
5
This specification does not apply for cabinets more
than a horizontal distance of 10” (25.4 cm) from the
edge of the range.
Suggested
location of
utilities
3
Grate
level
G
10" (25.4 cm) min.
to combustible side
walls above the range
(on both sides)
non-combustible
rear wall (recommended)
H
Backsplash
3/8" (1.0 cm)
min. for downdraft cap
clearance
J
Note 2
Cutout tolerances: +1/16” (+1.6 mm), -0
unless otherwise stated