Panasonic 931063 Dual Zone Mini Split System with 2 CSE9RKUAW Wall Mount Indoor Unit, 18000 Cooling and 24600 Heating BTU Total Capacity

User Manual - Page 4

For 931063.

PDF File Manual, 14 pages, Read Online | Download pdf file

931063 photo
Loading ...
Loading ...
Loading ...
30
9.2 CU-4E24RBU
9.2.1 Check Points
Allowable
elevation:
15 m (49.2 ft) max.
elevation between
The allowable
each of the indoor
units and between
the indoor and
outdoor units.
Flexible cord x 4 core
(polychloroprene sheathed)
(Not included in the unit)
(Not included in the unit)
(Not included in the unit)
Unit B
Unit C
Unit D
Unit A
Applicable connecting tube kit:
CZ-3F type
Unit A Maximum pipe length: 25 m (82.0 ft)
Unit B Maximum pipe length: 25 m (82.0 ft)
Unit C Maximum pipe length: 25 m (82.0 ft)
Unit D Maximum pipe length: 25 m (82.0 ft)
Indoor/outdoor unit
connection cables
Flexible cord x 4 core
(polychloroprene sheathed)
(Not included in the unit)
Flexible cord x 4 core
(polychloroprene sheathed)
Outdoor unit power supply:
Single-phase 208-230V, 60Hz
45A switch
(circuit breaker)
(Not included in the unit)
Flexible cord x 3 core
(Not included in the unit)
Outside
wiring work
Grounding work
Total maximum pipe length: 70 m (229.6 ft)
Air purging: Air purging by vacuum pump.
Loading ...
Loading ...
Loading ...