Service and Adjustment
Tank (Sediment) Cleaning
Sediment build-up on the tank bottom may create varying
amounts of noise, and if left in the tank will cause premature
tank failure. In some water areas, you may not be able to drain
all sediment deposits by simply draining the tank. in these cases
Mag Erad (part no. 23600) can be used to help remove the sedi-
ment deposits. This may be ordered from the Sears Service
Center. For ordering, refer to cite "Parts Order List" section.
AWARNING I
Soot build-upindicatesa problem that requires correction[
beforefurtheruse.Turn "OFF" gasto waterheaterand leave
"OFF" until repairs are made, becausefailureto correctthe
causeofthe sootingcan result in a fire or explosioncausing
DEATH,SEROUSBODILYINJURY,ORPROPERTYDAMAGE.
Venting System Inspection
At least once a year a visual inspection should be made of the
venting system. You should look mr:
Obstructions which could cause improper venting. The com-
bustion and ventilation air flow must not be obstructed.
Damage or deterioration which could cause improper venting
or leakage products.
of combustion
Rusted flakes around top of water heater.
AWARNING
Chemicalvapor corrosionof the flue and vent systemmay
occurif air for combustioncontainscertainchemicalvapors.
Spraycanpropellants,cleaningsolvents,refrigerator and air
conditionerrefrigerants, swimmingpool chemicals,calcium
and sodiumchloride,waxes,bleach,andprocesschemicalsare
typicalcompoundswhicharepotentiallycorrosive.
A WARNING
Obstructedor deterioratedventsystemsmaypresentaserious
healthrisk orasphyxiation.
AWARNING I
Be sure the vent piping is properly connected to prevent
escapeof dangerousflue gasseswhich could causedeadly
[ asphyxat on. I
AWARNING ]
If after inspectionof the vent systemyou foundsootingor/
deterioration,somethingiswrong.Callthe localgasutility to1
correctthe problemand cleanor replacetheflueandventing|
beforeresuming operationofthe water heater. ]
Burner Inspection
Burner Cleaning
In the event your burner needs cleaning, use the following
instructions:
If inspection of the burner shows that cleaning is required, turn
the gas control knob clockwise (_"',) to the "OFF" position,
depressing slightly.
NOTE: The knob cannot be turned from "PILOT" to "OFF"
unless knob is depressed slightly. DO NOT FORCE.
Loose deposits on or around the burner can be removed by care-
fully using the hose of a vacuum cleaner inserted through the
access door of the water heater. If the burner needs to be removed
for additional cleaning, call the Sears Service Center to remove
and clean the burner and correct the problem that required the
burner to be cleaned.
AWARNING
Do not usethisapplianceifanypart ofit hasbeenunderwater.
] Immediately call a SearsService Technicianto inspectthe I
I appliance and to replace the gascontrol or anypart ofthe
I burnersystemwhichhasbeenunder water. I
At least once a year a visual inspection should be made of the
main burner and pilot burner. The drawing is for your reference.
You should check for sooting which is not normal acid will
impair proper combustion.
L.P.Gas Control Valve & Burner
Assembly Replacement
Information
AWARNING
PROPANE (L,P.) GAS CONTROL VALVE AND BURNER
ASSEMBLY REPLACEMENT INFORMATION.
For Propane (L.P.) Gas Models Only:
Your water heater is equipped with a Propane (L.R) gas
control valve and a main burner assembly with left hand
threadsfor the followingfittings andtheir connections.
(I) The connection between the manifold and the
gas control valve (A to B) are left hand threads.
(2) The connection between the main burner ori-
fice and the manifold (C to D) are left hand
threads. For ordering these replacement parts,
please refer to the "Parts Order List" section of
this manual.
2O