Jenn-Air JJW9630CAS Built-In 30” Electric Wall Ovens

Installation Instructions - Page 2

For JJW9630CAS.

PDF File Manual, 6 pages, Read Online | Download pdf file

JJW9630CAS photo
Loading ...
When
installing
a
27”
wall
oven
under
a
30”
cooktop
some
interference
may
occur.
The
following
cutout
notching
of
the
side
trims
will
eliminate
the
interference
of
the
side
trim
to
the
burner
box.
After
cutting,
file
the
side
trim
edges
to
eliminate
burrs.
i)
NN
“PT
CAUTION
For
European
style
cabinets
(flush
front)
the
required
clearance
for
operation
of
the
oven
door
is
minimum
spacing
of
7/8"
between
the
cutout
and
the
door,
hinge
or
drawer
of
the
cabinet.
Some
built-in
cabinets
may
not
be
wide
enough,
due
to
their
construction,
to
allow
this
installation.
1.
Cut
hole
in
cabinet
to
mount
oven.
Cutout
in
cabinet
should
be
level
and
straight.
NOTE:
There
are no
provisions
to
level
the
unit
after
it
is
installed.
An
oven
that
is
not
level
could
cause
poor
baking
results.
2.
Install
plywood
floor
as
shown.
3.
Attach
unit
to
the
cabinet
with
four
No.
8 x
1”
screws
supplied
with
unit
inside
of
envelope
containing
these
instructions.
Pre-drill
holes
in
cabinet
for
attachment
screws
using
1/8”
drill.
Oven
mounting
holes
are
provided
in
side
trim.
4.
See
instructions
at
right
for
electrical
hook-up.
5.
See
Use
and
Care
Manual
for
operating
instructions.
Installing
Bottom
Trim
Piece
Electrical
Connections
Unit
to
be
properly
circuit
protected
and wired
according
to
local
electrical
code
and
National
Electrical
Code.
It
is
advisable
that
the
electrical
wiring
and
hookup
be
accomplished
by
a
competent
electrician.
120/240
VAC
or
120/208
VAC
60 Hz.
See
serial
plate
on
front
of
unit
for
power
requirements.
The
neutral
of
this
unit
is
grounded
to
the
frame
through
the
green
or
solid
grounding
wire.
(The
green
and
the
white wires
are
twisted
together
at
the
termination
of
the
conduit.)
If
used
on
new
branch-circuit
installations
(1996
NEC),
mobile
homes,
recreational
vehicles,
or
in
an
area
where
local
codes
prohibit
grounding
through
the
neutral
conductor,
untwist
or
disconnect
the
green
wire
and
connect
the
green
wire
to
ground
in
accordance
with
local
code.
Connect
the
white
neutral
to
the
service
neutral.
Connect
all
wires
to
the
branch
circuit
with
approved
connectors.
Use
copper
or
aluminum
wire.
If
aluminum
wire
is
used,
use
connectors
recognized
for
joining
aluminum
to
copper.
The
chart
below
recommends
the
minimum
circuit
protection
and
wire
size
if
the
appliance
is
the
only
unit
on
the
circuit.
RECOMMENDED
MINIMUM
K.W.
RATING
CIRCUIT
PROTECTION
WIRE
SIZE
ON
SERIAL
PLATE
IN
AMPERS
(AWG)
0-
48
20
12
49
-
69
30
10
70
-
99
40
8
10.0
-
11.9
50
8
12.0
-
149
60
6
Service
Interrupt
the
source
of
electricity
to
the
unit
when
attempting
to
repair
or
service
the
oven.
Failure
to
do
this
could
result
in
a
dangerous
or
even
fatal
shock.
IMPORTANT
-
SAVE
FOR
LOCAL
ELECTRICAL
INSPECTOR’S
USE
Loading ...