Venting system must terminate to the
outside,
Do not terminate the vent in an attic or
other enclosed space,
Do not use four-inch laundry-type wall
caps,
Do not use plastic vent,
Vent system needed for installation is not
included. Backdraft damper supplied with
product must be used, If roof or wall cap
has a damper, do not use damper supplied
with hood, Use metal vent only, Rigid metal
vent is recommended,
Determine which outside venting method
you need to use,
The length of the vent and number of
elbows should be kept to a minimum to
provide efficient performance, The size of
the vent should be uniform, Do Not install
two elbows together, Use duct tape to seal
all joints in the vent system, Vent can
terminate either through the roof or wall,
Use caulking to seal exterior wall or roof
opening around exhaust hood, For the
most efficient and quiet operation, it is
recommended that the range hood be
vented vertically through the roof using 7"
round vent,
Figures ]-4 show common venting methods
and what types of materials are needed,
Verticalroofventing
roof cap
7" round _ "b -
throu_
damper _ ] I J l
located as far I I I J
from hood as ] I _ I
possible __ __
3-114" x 10"
66,,_ to 7" tiffing
Figure ]
Verticalroofventing
3-1/4" x 10"
through the roof
roof cap
J
Figure 2
Panel B
Horizontalwall venting
3-114" x 10"
through the
wall cap
Figure 3
roof cap
7" min. diameter
round vent
3-114" x 10" to round
vent transition
Figure 4
wall cap
Recommended vent length
Use 3-1/4" x 10" or 7" vent with a maximum
length of 26 feet for vent system, For best
performance, use no more than three 90 °
elbows, To calculate the length of system
you need, add the equivalent feet for
each vent piece used in the system, See
the following examples,
3= ]/4" x ] 0" vent system
3-1/4" x 10" b_6 ft.
Maximum lengf
] ] 2 ft. ] - 90 ° elbow
____ 8 feet straight
II 1-walleap
Length of 3-1/4" x
10" system
wall cap
= 26 feet
= 5 ft,
= 8 ft,
= 0 ft,
=13 ft,
Recommended standard fiffings
3-1/4" x 10" go ° 3-1/4" x 10" flat 3-1/4" x 10" wall
elbow = 5 ft. elbow = 12 ft. cap = 0 ft.
7" vent system
go ° elbow
2
/
3-114" x 10"
to 7"
transition
_(-_6 ft. --
T _ycap
2 ft.
_!_
Maximum length = 26 feet
1 - transition = 4,5 ft,
2- 90 ° elbows = 10 ft,
] -wallcap = 0 ft,
8 feet straight = 8 ft,
Length of 7" system = 22,5 ft,
Recommended standard fittings
3-1/4" x 10" to 3-1/4" x 10" to 7" 90 ° elbow = 5 ft,
7" = 4.5 ft. 90 ° elbow = 5 ft,
45 ° elbow : 2.5 ft.
7" wall cap = 0 ft.
Now start...
With range hood in kitchen.
Slide cardboard or hardboard under range
before moving range across floor to
prevent damaging floor covering.
Cover countertop, cooktop or set-in range
with a thick, protective covering toprevent
damaging countedop.
[] Disconnect and move freestanding
range from cabinet opening to provide
easier access to upper cabinet and rear
wall, Put a thick, protective covering over
cooktop, set-in range or countertop to
protect from damage or dirt,
[] If your range hood is a vented-only
model, determine which venting method
(roof or wall venting) you need to use,
If your range hood isa non-vented=
(recirculating) only model, go to Step 3a,
Panel D,
To install a
yented-only model
Installatlon:
rectangular vent
knockouts
wiring
knockouts
[] Remove knockout from the wiring
opening (top or rear) to be used,
For rectangular venting, remove only the
3-1/4" x 10" rectangular opening knockout
for the venting method (roof or wall) you
have selected,
terminal
-box
cover
[] If your model does NOT have a
factory installed power cord, remove
terminal box cover from range hood,
Excessive Weight Hazard
Use two or more people to move and
install range hood.
Failure to follow this instruction can
result in back or other injury.
keyhole slot
front
hood
[] Lift the range hood into final
position and center, Mark on the underside
of cabinet the location of the four keyhole
mounting slots, Set range hood aside on a
protected surface,
Loading ...
Loading ...