PRODUCTDATASHEETS
Base Grille Water Filtration System
Model WF-L200V Capacity 200 Gallons (757 Liters)
Model WF-NL120V Capacity 120 Gallons (454 Liters)
System tested and certified by NSF International agah_st NSF/ANSI
Standard 53 fo_ the reduction of Lead, Mercury, Benzene,
p=dichlorobenzene, O=Dichlo_obenzene, Toxaphene, Ethyl Benzene,
reduction of Chlorine Taste and Odor and Particulate Class H L
1,2,4=t_ichlorobenzene and against NSF/ANSI Standard 42 for the
This system has been tes_d according to ANSVNSF 42/53 for the reduction of the substances listed below. The concentration of the
indicted substances in water entering the system was reduced to a o3ncentration less than or equal to the permissible limit for water
leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction
Chlorine Taste/Ode[ _50% 1.9 mg/L 0.06 mg/L >75% >75%
Ioo 'co'a'eO'ass'"I 14033 / ,L 1 '2/m 198.7 IgP.0
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum % Average %
Reduction Requirements Influent Concentration Effluent Effluent Reduction Reduction
Lead:@pH 6.5 0.01mg/L 0.14 mg/LT 0.15 mg/L _ 10% 0.0014 mg/L 0.0011 mg/L 99.00% 99.21%
Lead: @pH 8.5 0.01mg/L 0.15 mg/L t 0.15 mg/L ± 10% 0.0069 mg/L 0.0042 mg/L 95.40%% 97.20%
Mercury: @pH 6.5 0.002 mg/L 0.0059 mg/L 0.006 mg/L _ 10% 0.0009 mg/L 0.0004 mg/L 84.74% 93.22%
Mercury: @pH 8.5 0.002 mg/L 0.0054 mg/L 0.006 mg/L _ 10% 0.0007rag/L 0.00043 mg/L 87.03% 92.03%
Benzene 0.005 mg/L 0.0157 mg/L 0.015 mg/L _ 10% 0.002 mg/L 0.00083 mg/L 87.26% 94.71%
3 dichlorobenzene 0.075 mg/L 0.210 mg/L 0.225 mg/L _ 10% 0.0005 mg/L 0.0005 mg/L 99.76% 99.76%
O Dichlorobenzene 0.60 1.84 1.8 ± 10% 0.20 0.0418 89.13 97.73
Toxaphene 0.003 0.0143 0.015 ± 10% 0.0012 0.0010 91.60 93.00
Ethyl Benzene 0.70 2.00 2.1 ± 10% 0.40 0.085 80.00 95.75
1,2,4 trichlorobenzene 0.07 0.232 0.21 ± 10% 0.0041 0.0016 98.23 99.31
Test Parameters: pH = 7.5 ± 0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°0).
• It is essentialthat operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
• Model WF-L200V: The filter monitor system measures the
amount of water that passes through the tiger and alerts you
to replace the filter. When 90% of the filter's rated Ige is used,
the filter indicator light changes from green 1oyellow. When
100% of the filter's rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the tiger. Use replacement cartridge L20OV/NL120V,
part #4396701. 2004 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model WF-NLf20V: Change the water filter cartridge every 6-
9 months. Use replacement cartridge L200V / NL12OV, part
#4396701. 2004 suggested retail price of $32.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
• The product is for cold water use only.
• Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
• Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
• Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 120 psi (207 - 827 kPa)
Water Temperature 33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate 0.5 GPM (1.9 Wmin.) @ 60 psi.
*Class Ill par[iole size: > 5 to < 15 um
*_Test requirement is at least 100,00O par ticles/m L of AC Fine Test Dust.
I_h ese contaminators are not necessarily in your water suppl_ Performance may vary based on Ioc_ water conditions,
® NSF is a registered trademark of NSF Internation_.