Installation
55
EN
5.5 Adaptation to different types of
gas
In case of operation with other types of gas,
the burner nozzles must be changed and
the minimum flame adjusted on the gas
taps.
Changing the nozzles
1. Remove the grids from the hob.
2. Remove the flame-spreader crowns and
relative burner caps.
3. Replace the burner nozzles using a 7 mm
socket wrench according to the gas to
be used (see "Nozzle and burner
specification tables").
4. Reposition the burners in their respective
housings.
The nozzle tightening torque must
be no more than 3 Nm.