Craftsman 580327360 generator

User Manual - Page 20

For 580327360.

PDF File Manual, 60 pages, Download pdf file

Loading ...
Loading ...
Loading ...
Probmem
Engine is running, hut no AC output is
availaMe.
Engine runs good at nooload hut "hogs
down" when loads are connected.
Cause
f. One of the circuit breakers is open,
2. Faultin generator,
3. Poor connection or defective cord
set,
4. Connected deviceis bad.
,
2.
3.
4.
Short circuit in a connected load. 1.
Enginespeed is too slow. 2.
Generator is overloaded. 3.
Shorted generator circuit. 4.
1. Rocker Switch set to "Off".
2. FuelValve is in "Off" position.
3. Dirty air cleaner.
4. Out of fuel.
5. Stale fuel.
6. Spark plug wire not connectedto
Correction
1. Resetcircuit breaker.
2. ContactSears service facility.
3. Checkand repair.
4. Connectanother device that is in
good condition.
Disconnect shorted electricaI load.
ContactSears service faciiity.
SeeDon't OverloadGenerator.
ContactSears service facility.
1. Set switch to "On".
2. Turn fuel valveto "Open"position.
3. Cleanor replaceair cleaner.
4. Fill fuei tank.
5. Drain fuel tank and carburetor; fill
with fresh fuel.
6. Connectwire to spark plug.
Engine will not start; or starts and runs
rough.
spark piug.
7. Badspark piug.
8. Water in fuel.
9. Flooded.
7. Repiacespark plug.
8. Drain fuel tank and carburetor; fill
with fresh fuel.
9. Wait 5 minutes and re-crank
engine.
10. Excessiveiyrich fuel mixture.
11. Intake valvestuck open or ciosed.
12. Enginehas lost compression.
Out of fuel.
10. ContactSears service faciiity.
11. ContactSears service faciiity.
12. ContactSears service facility.
Fiflfuel tank.
1. Load is too high.
2. Dirty air filter.
Carburetor is running too rich or too
lean.
Engine shuts down when running.
1. SeeDon't OverloadGeneratof:
Engine lacks power. 2. Replaceair filter.
Engine "hunts" or falters. ContactSears service facility.
2O