TheStatStationTM displaysthe nominai ioad on generator
based on output frequency. It also has a built in maintenance
reminder.
Wattage Monitor Operatian
The dispiay is two seven-segment LEDsthat provide an easy-
to-read indication of the amount of power being suppiied by
the generator. The ioad monitor displays the generator's
output as a percentage.
As generator ioad increases,the dispiay vaiues wiii increase.
When the dispiayedvalues begin flashing, the user should
stop adding electricaI ioads to the generator.
If the power usage becomestoo higI1,the ietters "OL" (for
Over Load)will flash on the display. The user should reduce
the amount of load attached to the generator.
_laintenanee Reminder
The LEDwill display certain codes to aiert you to check oii,
change off, check or replaceair fiiter and check or replace
spark piug. The foliowing codes wiii display:
"C1" Check oii at 8 hour increments
"C2" Changeoil at 50 hour increments
"C3" Check or repiace air fiiter at 25 hour increments
"C4" Check or repiace spark piug at 100 hour increments
To take advantage of the StatStation "maintenance reminder"
capabilities, tile user must press tile resetbutton after
compbting the maintenancecatied for in the dispiayedcode
(Cl, C2, C3, or C4). This results in a display of "Co" or "CA",
depending on how iong the button is pressed:
1) "Co" = Pressingthe reset button once quickiy wiii
display "Co"(clearing to zero). This wilI clear any
maintenancecodes that haveelapsed up to that point
and they wiii begin timing againfrom zero.
2) "CA" - Pressing and honing the resetbutton for
2 seconds wilI display "CA"(clearing all). This clearsalI
maintenancecodes, even if they have not yet reached
their service point, and they will begin timing again
from zero.
If nominal Ioad and maintenancecodes appear
simuItaneously, the LEDshall display, alternately, the
nominal Ioad and code as follows:
The code wilI display for 3 seconds, then 1/2 second off. The
load will display for 6 seconds and then 1/2 second off.
Engine Maintenance
WARNING
Unintentionai sparking can result in fire or
electric shock.
WHEN ADJUSTINGOR [VIAKmNGREPAIRSTO YOUR GENERATOR
, Disconnectthe sparkplugwirefromthe sparkplugandplace
thewirewhereit cannotcontactsparkplug.
WHEN TESTINGFORENGINESPARK
, Useapprovedsparkplugtester.
DONOTcheckfor sparkwithsparkplugremoved.
oim
Oil Recommendations
NOTE:Usea Ngh quality detergent oiI ciassified "For Service
SF,SG,SH, SJ" or higher. DO NOTuse special additives.
1. Choosea viscosity according to the table below:
104 F ,w.__ !
86
68
5O
32
14
4
-22
40 C
o 30
20
10
_ 0
-10
-20
-30
NOTE:Synthetic oii meeting iLSAC GF-2,APi certification
mark and API service symbol with "SJ/CFENERGY
CONSERVING"or higiler, is an acceptabieoii at aii
temperatures. Use of synthetic oil does not alter required oil
change intervals.
SAE38: 40°Fand h,L@er(5°6 and higher) is good for alI
purpose use above 40°F, use below 40% will causehard
starting.
t0W-30:0 to IO0°F (-18 to 38°C) is better for varying
temperature conditions. This viscosity improves cold weather
starting, but may increaseoil consumption above 80%
(27°6).
*Check oii ievel frequently at higher temperatures.
Synthetic 5W-38:=20 to 120°F (-30 to 40 °C)provides the
best protection at ati temperatures as weii as improved
starting with iess oii consumption.
5W-30: 40°F and below (5°C and bdovv) is recommended
for winter use and works best in cold conditions.