or4B. POWER CORD CONNECTIONS
(3-Wire Connection instructions. For existing installations ONLY -
Refer to Fig. 13).
1. Follow the manufacturer's installation instructions supplied with the
strain relief and install (Also see Figs. 9, 10 & 11).
2. Insert the end connectors for Line 1, Line 2 and Neutral and tighten
securely to the terminal block (See Fig. 13).
IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3 nuts
are loosened or removed.
3. Make sure all connections are tightened securely and replace the rear
access cover (See Fig. 9).
Grounding instructions (3-Wire Connections only): A ground strap is
installed on this range which connects the center terminal of the terminal
block (Neutral) to the range chassis. The ground strap is connected to the
range by the center, lowest screw (See Fig. 13). The ground strap must not be
removed unless National, State or Local Codes do not permit use of a ground
strap.
NOTE: If the ground strap is removed for any reason, a separate ground wire
must be connected to the separate ground screw attached to the range
chassis and to an adequate ground source.
4c. 3 & 4-WIRE PERMANENT WIRE CONNECTIONS.
3 =Wire Permanent Connection =follow Steps 1,2 & 5 below.
4 =Wire Permanent Connection =follow Steps 1 thru 5 below.
Before wiring the range, review the suggested power source location
drawings in Fig. 3. If connecting to a 4-Wire electrical system (new branch-
circuit or mobile home requires 4-Wire connection):
3-Wire Connection
Connect
line 1
here
Terminal
block
3 Factory installed connections
(DO NOT LOOSEN)
Connect
neutral
(white or
center) here
Connect
line 2
here
Ground screw
& ground Ic
NOTES:
Install strain=relief
bushing. Center or white
wire must always be
attached to the center
terminal on block
Fig. 13
FOR 3 & 4=Wire Permanent Connections
Tighten all 3 Terminal
wire leads block
1. (3 & 4 =Wire Permanent Connections) Follow the manufacturer's
installation instructions supplied with the strain relief and install.
2. (3 & 4 - Wire Permanent Connections) Strip insulation away from the
ends of the permanent wiring for Line 1, Line 2, Neutral (also strip ground
wire on 4-Wire Connections). Tighten all 3 wire leads to the terminal
block (Follow wire locations shown in Fig. 14).
IMPORTANT NOTE: DO NOT LOOSEN the factory installed nut
connections which secure the range wiring to the terminal block.
Electrical failure or loss of electrical connection may occur if these 3 nuts
are loosened or removed. NOTE: For 3=Wire Permanent Connections
skip Steps 3 & 4 and continue with Step 5.
3. (4=Wire Permanent Connection ONLY) Disconnect the ground strap.
Remove the factory installed ground screw & plate to release the factory
installed copper ground strap from frame of the appliance. Cut and
discard the copper strap from the terminal block. KEEP the ground screw,
ground plate and go to Step 4.
4. (4=Wire Permanent Connection ONLY) Connect the ground wire lead
(Green) to the frame of the appliance using the ground screw & plate as
shown in Fig. 15. Be sure to install using the same hole in the frame
where the ground screw was originally installed.
5. (3 & 4 - Wire Permanent Connections) Make sure all connections are
tightened securely and replace the rear access cover (See Fig. 9).
NOTE: Non=terminated field wire compression connections must be set
at 22 in./Ibs, or greater. Always use 10 gauge wire or larger.
5. CAREFULLY SLIDE RANGE iNTO FINAL LOCATION.
Be sure to provide all the adequate clearances and dimensions shown in
Figs. 1, 2 & 3 before moving appliance into final location. Carefully slide range
into final position while inserting rear leveling leg into and FULLY ENGAGING
THE ANTI-TIP BRACKET (See Fig. 7). Make sure the power cord folds into the
remaining open floor area behind the range Warmer or storage drawer. Be
sure to check the level of the range.
Line 1
Line 2
Ground plate
Ground screw
Ground strap
Fig. 14
Note: Non-terminated field wire compression
connections must be set at approximately 22in./
lbs. Always use 10 ga. wire or larger.
GROUND
SCREW
GROUND
,_=
WIRE LEAD
Serial Plate Location
PROPER
GROUND FOR
4=WIRE
_D PERMANENT
CONNECTION
Fig. 15
Serial plate location:
Serial plate is located on the lower right front frame
of the appliance