7
Timer Icon: Timer icon illuminates when the timer function is enabled.
(2) Understand the Control Buttons
Power Switch: Press to turn the dehumidifier ON or OFF.
Up Button: Press to increase the set-point of humidity level or timer.
Down Button: Press to decrease the set-point of humidity level or timer.
Timing/Function Button: Press once to check the settings. Press and hold for 3 seconds to
enter Timer setting system.
6. General Operation Instructions
(1) Turn the dehumidifier on
Press the Power Switch to turn the dehumidifier on.
(2) Set a desired humidity percentage value
Press or button to set your desired humidity percentage value between 1%-98% in
increment of 1%. 40%-60% is a general humidity setting guide. After selected the target
value, press Timing/Function Button to confirm your setting, or let the setting be
registered automatically after 5 seconds of no operations on the control panel.
Note:
· The dehumidifier with a humidistat will stop and start automatically to maintain the inlet
humidity level the user has set. For example, if the set humidity is 50%, when the inlet
humidity level the dehumidifier detects is 47%, 3% lower than the set humidity, the
dehumidifier will automatically stop and enter into “wet controller” mode. When the inlet
humidity level the dehumidifier detects raises to 53%, 3% higher than the set humidity, it
will automatically restart.
· However, if the set humidity level is equal to or lower than 30, the dehumidifier will
enter CONTINUOUS MODE where the dehumidifier will run continuously.
(3) Turn the dehumidifier off
Press the Power Switch to turn the dehumidifier off.
Note: To protect the compressor, the fan will continue to operate for 5 seconds after the
dehumidifier has shut off. So please do not disconnect the power cord to force the
dehumidifier to stop. Always use the power button.