Burner and nozzle characteristics tables
1 Natural gas G20 - 20 mbar AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 72 97 133
Pre-chamber (printed on nozzle) (X) (Z) (S)
Reduced flow rate (W) 400 500 1600
2 Natural gas G20 - 25 mbar AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 72 94 128
Pre-chamber (printed on nozzle) (X) (Z) (S)
Reduced flow rate (W) 400 500 1600
3 Natural gas G25/G25.3 - 25 mbar AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 72 94 128
Pre-chamber (printed on nozzle) (F1) (Y) (S)
Reduced flow rate (W) 400 500 1600
4 Natural gas G25.1 - 25 mbar AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 77 100 145
Pre-chamber (printed on nozzle) (F1) (Z) (F3)
Reduced flow rate (W) 400 500 1600
5 Natural gas G25 - 20 mbar AUX SR UR-3c
Rated heating capacity (kW) 1.05 1.8 3.5
Nozzle diameter (1/100 mm) 77 100 145
Pre-chamber (printed on nozzle) (F1) (Y) (F3)
Reduced flow rate (W) 400 500 1600
6 Natural gas G2.350 - 13 mbar AUX SR UR-3c
Rated heating capacity (kW) 1.0 1.8 3.6
Nozzle diameter (1/100 mm) 94 120 200
Pre-chamber (printed on nozzle) (Y) (Z) (H3)
Reduced flow rate (W) 400 500 1600