Troubleshooting
Before calling
Before calling for service, review this list. It may save both time and expense. The list
includes common occurrences that are not the result of defective workmanship or
materials in this dryer.
PROBLEM POSSIBLE CAUSES SOLUTIONS
Dryer does
not start.
Electrical power cord is not
securely plugged in or plug
may be loose.
House fuse blown or circuit
breaker tripped.
Action of pressing start but-
ton on “touch screen” style
console not recognized
Thermal limiter tripped.
Delay time inadvertently
activated.
Door may be open. Unit will
not operate with door open.
Make sure the plug fits tightly in
wall outlet.
Reset circuit breaker or replace
fuse.
Make sure electrical line is not
overloaded and the dryer is on a
separate circuit.
Press start button with bare fin-
gertip.
Call authorized service person for
replacement.
Ensure delay time not activated.
Ensure door is closed.
LED
displays
”.
Dryer has been programmed
to temporarily perform a
repeating demo cycle.
Reset the unit back to factory de-
fault settings as described earlier.
Dryer runs
but won’t
heat.
There are 2 house fuses in
the dryer circuit. If 1 of the 2
fuses is blown, the drum may
turn but the heater will not
operate (electric models).
Gas supply valve is not open
(gas models).
Dryer does not have enough
air supply to support the
burner flame (gas models).
LP gas supply tank is empty
or there has been a utility
interruption of natural gas
(gas models).
Replace fuse.
Check to make sure supply valve
is open. Refer to the installation
instructions provided with the dryer.
See the
Installation
sections of this
guide.
Refill or replace tank. Dryer should
heat when utility service is restored.