Kenmore 41794072300 dryer

User Manual - Page 9

For 41794072300.

PDF File Manual, 20 pages, Download pdf file

Loading ...
Loading ...
Loading ...
GREEN
GROU
SCREW
NEUTRAL
GROUND
WIRE
MOU
SILVER TERMINAL
GRE
GROUND
SCREW
GREEN POWER
GROUND WIRE
CORD
SILVER TERMINAL
TERMINAL BLOCK
NUT
TIGHTEN NUT
TO THESE
THREADS
GROUND
WIRE
RE
STRAIN
RELIEF
MOUNTING
BRACKET
POWER
CORD
NUT
TIGHTEN
NUT
TO THESE
THREADS
BRACKET POWER CORD
ELECTRICAL CONNECTIONS
FOR 3-WIRE SYSTEM
[ ELECTR/C Dryer
I,
,
,
,
,
Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.
Install a U.L. approved strain relief into the power cord
entry hole of the mounting bracket. Finger tighten the nut
only at this time.
Thread a U.L. approved 30 amp. power cord, NEMA
10-30 type SRDT,through the strain relief.
Attach the power cord neutral (center wire) conductor to
the silver colored center terminal on the terminal block.
Tighten the screw securely.
Attach the remaining two power cord outer conductors to
the outer brass colored terminals on the terminal block.
Tighten both screws securely.
Do not make a sharp bend or crimp wiring/
conductor at connections.
6. Reattach the strain relief mounting bracket to the back of
the dryer with two screws. Tighten screws securely.
7. Tighten the screws securing the cord restraint firmly
against the power cord.
8. Tighten the strain relief nut securely so that the strain
relief does not turn.
9. Reinstall the terminal block cover.
ELECTRICAL CONNECTIONS
FOR 4- WIRE SYSTEM
ELECTR/C Dryer ]
I,
,
,
,
5.
6.
,
Remove the screws securing the terminal block access
cover and the strain relief mounting bracket located on
the back of the dryer upper corner.
Install a U.L. approved strain relief in the entry hole of
the mounting bracket. Finger tighten the nut only at this
time.
Remove the ground wire from the green ground screw
located above the terminal block.
TYPICAL 4
CONDUCTOR BLACK
WHITE
30 AMP NEMA 14-30 TYPE SRDT OR ST
Thread a U.L. approved 30 amp power cord, NEMA 14-30
type ST or SRDTthrough the strain relief.
Attach the green power cord ground wire to the cabinet
with the green ground screw.
Attach the white (neutral) power cord conductor from the
power cord and the ground wire from the dryer harness to
the silver-colored center terminal on the terminal block.
Tighten the screw securely.
Attach the red and black power cord conductors to the
outer brass-colored terminals on the terminal block.
Do not make a sharp bend or crimp wiring/
conductor at the connections.
8. Tighten the screws securing the cord restraint firmly
against the power cord.
9. Tighten the strain relief nut securely so the strain relief
does not turn.
10. Reinstall the terminal block access cover.