Clean Filter Reminder
After 40 hours of operation, the clean filter reminder LED
above this button will illuminate indicating that the filters
need to be cleaned. When this indicator illuminates, clean
the filters as instructed on page 6. After cleaning, press this
button for 3 seconds to reset the 40-hour period and turn
the LED off.
Light On/Dim/Off
This button controls the halogen lighting. The first press
turns the lights on. A second press dims the lights. A third
press turns the lights off.
Heat Lamp (only on 27” depth models)
The buttons marked “L” and “R” independently control the
left and right infrared heating lamps, turning the lights on or
off.
Heat Sensor
Oven Temperature Condition
The high temperature sensor protects the hood from high
temperatures which may damage components. The control
is set to activate at 161° F (72° C) and reset at 140°F
(60°C). When activated, the ventilator will turn on low and
the corresponding LED will blink, indicating an oven
temperature condition.
While the high temperature sensor is activated, the blower
speed can be changed or turned off. If the blower is turned
off, the corresponding LED will blink. Light controls will
remain operational. When the control sensor reaches
140°F (60°C), a reset will occur. During reset, the control
will revert back to the operational state prior to the high
temperature condition.
High Temperature Fault Condition
The circuit is equipped with an alarm indicating that the
heat sensor protection is not working due to a damaged
sensor. In the case of this extreme condition, the three
speed indicator LEDs will start blinking. All the controls will
be operational except for the speed indicators.