INSTALLATION INSTRUCTIONS
Installation Instructions
1. GAS SUPPLY
WARNING
Fire Hazard: Do not use a
IODPHWRFKHFNIRUJDVOHDNV
WARNING
Explosion Hazard: Do not
H[FHHGIWOEVRIWRUTXHZKHQPDNLQJJDV
OLQHFRQQHFWLRQV2YHUWLJKWHQLQJPD\FUDFN
the pressure regulator resulting in fire or
explosion hazard.
WARNING
*DVOHDNVPD\QRWEH
detected by smell alone. Gas suppliers
recommend your purchase and install an
UL approved gas detector. Install and use
in accordance with the manufacturer's
instructions.
Gas Pressure Regulator
<RXPXVWXVHWKHSURSDQHJDVSUHVVXUH
regulator supplied with this range. For proper
operations the inlet pressure to the regulator
should be as follows:
0LQLPXPSUHVVXUH´RI:DWHU&ROXPQ
0D[LPXPSUHVVXUH´RI:DWHU&ROXPQ
&RQQHFWDSURSDQHVXSSO\OLQHZLWKD´)ODUH
Female connection to the regulator in the upper
right rear corner of the cabinet
Tighten the gas line to the regulator using 2
wrenches.
IMPORTANT:/HDYHDGHTXDWHVSDFHDURXQGWKH
gas supply pipe in case of bend or damage during
installation. Make sure the gas supply pipe cannot
contact any moving parts after installed.
When using pressures greater than ½ psi
N3DWRWHVWWKHJDVVXSSO\V\VWHPRIWKH
59GLVFRQQHFWWKHUDQJHDQGLQGLYLGXDOVKXWRII
valve from the gas supply piping. When using
SUHVVXUHVRIòSVLN3DRUOHVVWRSUHVVXUH
test the gas supply system, simply isolate the
range from the gas supply system by closing the
individual shut-off valve.
3. ELECTRICAL CONNECTION
The power supply wires are located at the top left
corner of the rear of the appliance.
&RQQHFWDSRVLWLYH9SRZHUVXSSO\ZLUHWRWKH
DSSOLDQFHEODFN9ZLUHDQGDQHJDWLYH9
SRZHUVXSSO\ZLUHWRWKHDSSOLDQFHZKLWH9ZLUH
Maximum current draw is less than 2 amp.
NOTE: Ensure to connect the wires with the
FRUUHFWSRODULW\%ODFNLV³´DQG:KLWHLV³´
Ensure electrical connections are properly
secured.
Ensure electrical supply lines are disconnected,
or power removed at the main fuse or circuit
breaker panel, before servicing the appliance.
2. LEAK CHECK
Ŷ Make sure all control knobs are in the OFF
position.
Ŷ$SSO\DJDVOHDNGHWHFWLRQOLTXLGWRWKH
connections. Any gas leaks will be indicated by
bubbles.
Ŷ If a gas leak is detected, tighten the loose joint,
or replace the faulty part with a replacement
part recommended by a GE Appliances
authorized retailer.
CAUTION
PRODUCT DAMAGE HAZARD
Connect to 12V DC service only.
Connect only to protected circuit fused for
not more than 15 Amps.
RANGE INSTALLATION
Propane Supply
Line Connection
Power Supply
Connection