26
CONNECTING ELECTRICITY
Connecting the House Power.
Caution! Do not turn on the house power until the installation is complete.
Feed the Power Supply Cable through the electrical knock out.
Wiring Box Connections.
Attach the White lead of the Power Supply (A) to the White lead of the Range
Hood (D) with a twist-on type connector.
Attach the Black lead of the Power Supply to the Black lead of the Range Hood
(B) with a twist-on type wire connector (C).
Connect the Green (E) (Green and Yellow) ground wire under the grounding
screw.
1
3
2
Hood
wiring
5HSODFHWKH´HOGZLULQJFRPSDUWPHQWFRYHUDQGWKHJUHDVH´OWHUV