LOCATION AND INSTALLATION/VENTILATION
(CONTINUED)
W
V
E
VENT HOOD
COMBUSTIBLE
MATERIALS
2-1/2”
[6.4]
6”
[15.2]
5”
[12.7]
FINISHED
FLOOR
DIMENSIONS IN
BRACKETS [ ] ARE
IN CM.
19”
[48.3]
[24.1]
ELECTRICAL
SUPPLY
LOCATION
18” [45.7]
MIN.
9-1/2”
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
INSTALLATION CLEARANCES 36” - ALL BACKGUARDS
FRONT VIEW
1
8
"
[3.2 mm]
ZERO CLEARANCE
ALLOWED TO NEAREST
COMBUSTIBLE SIDE
SURFACE
RANGE MODEL
W
V (MIN)
KRI36 36” [91.4] 30” [76.2]
NOTES:
SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
“E” IS ELECTRICAL SUPPLY ZONE.
“W” IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH SIDE OF THE RANGE. ALLOWANCE MAY BE
NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
“V” IS MIN. CLEARANCE TO VENTILATION HOOD.