Sunstone 1218012 SUN4B-LP 34 Inch Series Freestanding Liquid Propane Grill with 4 Stainless Steel Burners, Wind Guard, Drip Tray, Warming Rack, and Smoker Box, in Stainless Steel

User Manual - Page 20

For 1218012.

PDF File Manual, 27 pages, Read Online | Download pdf file

1218012 photo
Loading ...
Loading ...
Loading ...
Minimum Distances to Combustible Materials or other
Appliance ONLY, Non-Combustible materials do not apply!
From Counter to Overhead Structure
4’ to 6’ ft. Min.
Clearance
From Counter to Outdoor Vent Hood
48" Min. Clearance
From Floor to Counter Top
42" Min. Clearance
From Grill to Vent Hood Width
4”-6" Min. Clearance
From Appliance to Appliance
3" Min. Clearance
From Appliance to Combustible Material
24" Min. Clearance
Clearances to Non-Combustible Construction*:
A minimum of 4” to 6” clearance from the back of the grill to non-combustible construction is required for
the purpose of allowing the lid to open fully. It is desirable to allow at least 6” rear and side clearance to
construction above the cooking surface for counter space. If you’ll be using the rotisserie option, the space
is essential for motor and skewer clearance.
BODILY INJURY:Failure to maintain required clearances creates a fire hazard that may
result in property damage or serious personal injury.
Clearances to Combustible Construction**:
Minimum of 24” from the sides and rear of grill must be maintained to adjacent vertical combustible
construction, above the counter top level. You should take in account that there is a large volume of heat,
and smoke will exhaust from the rear of the grill. This may discolor or damage unprotected areas, do not
install under unprotected combustible construction without using a fire safe ventilation system.
A 24” minimum clearance must be maintained under the counter top to combustible construction. The
clearance can be modified by a use of an insulated jacket.
** DEFINITION OF COMBUSTIBLE MATERIAL - Anymaterials of a building structure or decorative
structure made of wood, compressed paper, plant fibers, vinyl/plastic or other materials that are capable of
transferring heat or being ignited and burned. Such material shall be considered combustible even though flame-
proofed, fire-retardant treated or surface-painted, or plastered.
ISLAND LOCATION ENCLOSED INSTALL
PAGE 15
ATTENTION:All Gas Grill Installations MUST HAVE MINIMUM TWO AIR-FLOW VENTS, either in
ELEVATED POSITION for Natural Gas or LOWERED POSITION for Liquid Propane. Your Warranty may
be VOID if island does not meet basic setup requirements.