Settlement of outdoor unit
Anchor the outdoor unit tightly and
horizontally on a concrete or rigid
mount with a bolt and nut 0.39" or
0.32" diameter (Purchased separately).
14 A _'1
r_ Air inl_ rzT_
l_/_ _ _ t
_Air outlet
Outdoor unit dimension ff(WxHxD) A(ff) B(fl)
2.78'xl .77'xl .05' 1.77' 0.94'
2.92'x2.30'x1.30' 1.84' 1.18'
3.02'x2.59'x1.40' 2.00' 1.28'
Condensate drainage of outdoor unit
(no for cooling only)
The condensate and defrosting water formd during heating
in the outdoor unit can be properly discharged by drainage
p_pe.
Installation method:Insert the drain connection into one of the
025 holes of the chassis and then connect drainage pipe with
drain nozzle. Insert drainage plugs into the other holes
(Only for>12000Btu's).
_12000 Btu's >18000 Btu's
connection
connection
Drainage
Plug