BGA1601 Page 11 / 13
SPECIFICATIONS
60,000 BTU/HR MODEL
• 40,000-60,000 BTU/hr (11.7-17.5 kW)
• Fuel Consumption:
1.8 - 2.7 pounds/hr (0.84 - 1.26 kg/hr)
• Fuel Orifice Port No.: 18
• Fuel Orifice Port Size: 0.0196" (0.50 mm)
• Average Air Temp. Rise: 200° F (111° C)
• Fuel: Propane/LP Gas
• Gas Supply Pressure to Regulator:
Max - Bottle Pressure, Min - 10 psig (68.9 kPa)
• Gas Supply Pressure Regulator Out:
10psig (68.9 kPa)
125,000 BTU/HR MODEL
• 75,000-125,000 BTU/hr (21.9-36.6 kW)
• Fuel Consumption:
3.5 - 5.8 pounds/hr (1.57 - 2.62 kg/hr)
• Fuel Orifice Port No.: 18
• Fuel Orifice Port Size: 0.030" (0.75 mm)
• Average Air Temp. Rise: 400° F (232° C)
• Fuel: Propane/LP Gas
• Gas Supply Pressure to Regulator:
Max - Bottle Pressure, Min - 20 psig (137.8 kPa)
• Gas Supply Pressure Regulator Out:
10psig (137.8 kPa)
85,000 BTU/HR MODEL
• 50,000-85,000 BTU/hr (14.6-25.0 kW)
• Fuel Consumption:
2.3 - 3.9 pounds/hr (1.05 - 1.78 kg/hr)
• Fuel Orifice Port No.: 18
• Fuel Orifice Port Size: 0.024" (0.60 mm)
• Average Air Temp. Rise: 200° F (111° C)
• Fuel: Propane/LP Gas
• Gas Supply Pressure to Regulator:
Max - Bottle Pressure, Min - 10 psig (68.9 kPa)
• Gas Supply Pressure Regulator Out:
10psig (68.9 kPa)
WIRING DIAGRAM
CONNECTION DIAGRAM SCHEMATIC DIAGRAM
If any original wiring as supplied with the heater must be replaced, it must be replaced with
type AWG 105ºC wire or it’s equivalent expet as indicated (’Type SF2-200. “SCI-250ºC)
ALL MODELS
• Electrical Input:
115V, 60 Hz, 1Ø, 2a Direct Spark Ignition
• Primary Flame Control:
Thermocouple operated gas valve
• Minimum Ambient Temp. Rating:
0°F (-17.8° C)
1/2021