Stiebel Eltron SHC_4 4 Gallon 6-Year Point-of-Use Tank Electric Water Heater

User Manual - Page 5

For SHC_4.

PDF File Manual, 36 pages, Read Online | Download pdf file

SHC_4 photo
Loading ...
Loading ...
Loading ...
ENGLISH
www.stiebel-eltron-usa.com SHC 2.5 / SHC 4 | 5
INSTALLATION
Technical Data
6. Technical Data
SHC 2.5 SHC 4
Item No. 233219 234046
Voltage 110–120 V 110-120 V
Wattage 1300 W 1300 W
Amperage 11.3 A 11.3 A
Phase Single, 1/N/PE Single, 1/N/PE
Frequency 50/60 Hz 50/60 Hz
Type of installation Under sink Under sink
Internal tank material Steel Steel
Enclosure material Plastic Plastic
Thermal insulation material Polystyrene Polystyrene
Color white white
Nominal water volume 2.65 gal 10 l 4 gal 15 l
Standby energy loss
1
0.37 kWh/day 0.39 kWh/day
Recovery time 18 minutes 27 minutes
Temperature setting range 86–140 °F 30–60 °C 86–140 °F 30–60 °C
Maximum operating pressure 150 psi 1.0 MPa 150 psi 1.0 MPa
Weight empty 15.9 lbs 7.2 kg 19.8 lbs 9.0 kg
Weight full 38.6 lbs 17.5 kg 52.9 lbs 24.0 kg
Water connections 1/2˝ NPT 1/2˝ NPT
1
Measured at 131°F / 55°C set point temperature in 68°F / 2C ambient air temperature.
6.1 Dimensions, SHC 2.5
18 11/16 (475)
1 1/16 (26.5)12 5/8 (320)
1 3/4" (45)
3 15/16" (100)
11 (280)
3 1/8 (80)
10 5/8 (270)
5 1/2" (140)
6.2 Dimensions, SHC 4
19 3/4 (501)
15/16 (23)13 7/16 (342)
1 15/16" (49)
3 15/16" (100)
12 5/8 (320)
3 1/8 (80)
12 1/2 (318)
7 7/8" (200)
7. General Recommendations
The installation must be carried out by licensed profession-
als. All state and local codes must be adhered to.
The manufacturer will not be liable for any damages because
of failure to comply with these installation instructions or
because of improper installation performed by an unqual-
ified installer.
NOTE:
The T&P valve must be manually vented monthly.
See 12.2, “Venting the T&P relief valve”, pg. 8
NOTE:
Choose a location that allows easy access for main-
tenance or servicing.
The water heater should be installed with at least
8˝ of clearance on the top and sides of the unit.
in. (mm)
Hot Water
Outlet
1/2″ NPT
male thread
Cold Water
Inlet
1/2″ NPT
male thread
in. (mm)
Hot Water
Outlet
1/2″ NPT
male thread
Cold Water
Inlet
1/2″ NPT
male thread
Loading ...
Loading ...
Loading ...