Schumacher XI14 140W Power Converter

User Manual - Page 4

For XI14.

PDF File Manual, 27 pages, Read Online | Download pdf file

XI14 photo
Loading ...
Loading ...
Loading ...
4
Always run a test to establish whether the converter will operate a particular piece of
equipment or device. In the event of a power overload, the converter is designed to
automatically shut down.
This safety feature prevents damaging the converter while testing devices and
equipment within the wattage range of the converter.
When using the vehicle’s 12 volt accessory port, this converter is designed to supply
60 to 70 watts when the vehicle is not running. With the vehicle’s engine running, it
can supply up to 100 watts. To use the full output, you must connect the converter
directly to your battery.
NOTE: The 100 watt limit is to accommodate the fuse ratings for all vehicles. Some
vehicles may allow the full output. If the fuse blows when you switch on the device
you are trying to use, you have to either use a smaller device or you must connect the
converter directly to the battery.
IMPORTANT: This converter uses a modied sine waveform (diagram A) which is not
quite the same as power company electricity (diagram B). For the following devices, we
strongly recommend that you use caution and check the device’s manual to make sure
it is compatible with modied sine waveform.
1. Switch mode power supplies
2. Linear power supplies
3. Class 2 transformers
4. Line lter capacitors
5. Shaded pole motors
6. Fan motors
7. Microwave ovens
8. Fluorescent and high intensity lamps (with a ballast)
9. Transformer less battery chargers
Using the converter with any of these devices may cause the device to run warmer
or overheat.
Modied sine waveform
produced by converter
Diagram A Diagram B
Pure sine waveform
typical of home AC outlet
Loading ...
Loading ...
Loading ...