INSTALLATION05
Space Requirements for Outdoor Unit
When installing 1 outdoor unit
300 or more
When the air outlet is opposite the
wall
1500 or more
When the air outlet is towards the
wall
300 or more
150 or more 600 or more
When 3 sides of the outdoor unit are
blocked by the wall
1500 or more
2000 or more
The upper part of the outdoor unit
and the air outlet is towards the wall
500 or more
300 or more
The upper part of the outdoor unit
and the air outlet is opposite the
wall
When the walls are blocking front
and the rear side of the outdoor unit
300 or
more
1500 or
more
Top view Side view
AiroutletAirintake
Airintake
Airoutlet
Figure Description
, Airflowdirection.
(Unit:mm)