Rinnai FM10LA 10L Flowmaster LP Gas Continuous Flow Hot Water System

User Manual - Page 14

For FM10LA.

PDF File Manual, 24 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
Rinnai 14 HW_GI_FM10 OIM
APPLIANCE MOUNTING METHOD
1. After determining the desired location for the water heater, use the
dimensions in the drawing right to measure and mark o󰀨 the positions of the
3 appliance mounting points
A
and the 4 heat shield mounting points
B
.
2. Install 3 suitable screws or bolts at the 3 appliance mounting points
A
.
IMPORTANT
1mm
Ensure to leave at least a 1mm gap between the
inner face of the xing and the wall. This gap is
necessary as it will facilitate the correct mounting
of the water heater in step 4.
3. Using suitable xings secure the heat shield ush onto the wall at the 4 heat
shield mounting points
B
.
IMPORTANT
This Way Up!
The heat shield is to be mounted
with the more rounded corners
facing upwards and with the folded
tabs facing the walls surface.
4. Using the keyed mounts points, hang the water heater onto the 3 appliance
mounting xings installed in step 2. Ensuring that all 3 mounting points are
securely engaged.
SERVICE CONNECTION POINTS
NOTE
See Table 1, (Specication table) for individual
appliance connection / tting dimensions.
These dimensions are NOT an indication of the
pipe sizes required.
An approved full ow isolation valve and disconnection
union MUST be tted to the cold water inlet.
A non return valve is not required unless required by local
regulations. Isolation valves MUST NOT be tted directly
to the appliance.
Purge gas and cold water supply lines to remove air and
swarf before nal connection of the appliance. Swarf in
either the gas or water supplies may cause damage or
malfunction. These are not covered by warranty.
4.
2.
A
C
L
3.
C
L
B
Propane Gas
1
2
3
Natural Gas
1
2
4
1
2
3
½’ Gas Adaptor with washer (supplied)
Gas Regulator (supplied)
½’ to ½’ Regulator inlet pressure test point (supplied)
4
¾’ to ½’ Regulator inlet pressure test point (supplied)
425 185
140
157.5
315
120
240
A
A
A
B
B
GENERAL INSTALLATION INFORMATION
Loading ...
Loading ...
Loading ...