Loading ...
Loading ...
53
BORA PROFESSIONAL 3.0
246
341
62
14,5
7
25
73
37
44
21
491
509
15,5
24,5
240
370
133,5 255,5
540
R3
BORA VENTILATION HANDBOOK
Technical data
Supply voltage 220 – 240 V
Frequency 50 / 60 Hz
Maximum power consumption 5.0 kW
Maximum power rating 20 W
Minimum fuse protection 1 x 0.5 A
Power supply cable length 1,5 m
Dimensions (width x depth x height) 370 x 540 x 73 mm
Weight (incl. accessories/packaging) 11.5 kg
Surface material SCHOTT CERAN
®
Cooktop power levels 1 – 9, P
Size of front cooking zone Ø 240 mm
Size of rear cooking zone Ø 200 mm
Front cooking zone output (power burner) 850 – 3000 W
Rear cooking zone output (normal burner) 700 – 2000 W
Size of front pan support 270 x 270 x 25 / 50 mm
Size of rear pan support 235 x 235 x 25 / 50 mm
Product description
Intuitive control knob
Variable heat retention function
Sunken gas burners
Automatic reignition
Dishwasher-safe pan supports
Childproong feature
automatic heat up function
precise electronic control
residual heat display
Demo mode
Scope of delivery
Gas cooktop PKG3
2 x control knobs
2 x connection cables for the control knobs
2 x cast iron pan supports
Gas nozzle set G20/20 mbar natural gas
Connection cable to the extractor
operating and installation instructions
height adjustment plate set
mounting straps
Adapter cylindrical-conical
Seal
Accessories
BORA gas nozzle set natural gas G20/10 mbar PKGDS2010
BORA gas nozzle set natural gas G20/13 mbar PKGDS2013
BORA gas nozzle set natural gas G20/20 mbar PKGDS2020
BORA gas nozzle set natural gas G25/20 mbar PKGDS2520
BORA gas nozzle set natural gas G20/25 mbar PKGDS2025
BORA gas nozzle set natural gas G25/25 mbar PKGDS2525
BORA gas nozzle set liquid gas G30/G31 28-30/37 mbar PKGDS3028
BORA gas nozzle set liquid gas G30/G31 50 mbar PKGDS3050
BORA Pro gas nozzle set liquid gas G31/G30 mbar PKGDS3130
BORA Pro gas nozzle set liquid gas G31/50 mbar PKGDS3150
BORA burner set PKGBS
BORA pan support small PKGTK
BORA pan support large PKGTG
Product- and planning instructions
The gas connection tube must be provided at the installation site (thread
diameter 1/2“ cylindrical)
Ensure su󹩴cient air supply below the gas cooktop. Either over the front of
the body (opening cross-section > 50 cm²) or over the plinth area (opening
cross-section > 150 cm²)
Provide a return ow aperture (opening cross-section > 1000 cm² per air
cleaning unit) for recirculation in the plinth area
Please note the local regulations and connection requirements applicable to
gas cooktops
Please note the special installation and workmanship guidelines for the gas
cooktop (see the operating and installation instructions)
When operating a gas cooktop with a cooktop extractor, the gas ame can
be affected (depending on the height of the power level on the cooktop
extractor)
The performance characteristics of the gas cooktop (e.g. heating times,
e󹩴ciency, etc.) are affected by the cooktop extractor. The cooktop extractor
also affects the heat input and distribution
If the gas cooktop is used in a model with two cooktop extractors, it is to be
installed at the side
Rotation by 180° possible during installation
PKG3
BORA Pro gas cooktop
BORA Vertriebs GmbH & Co KG · Innstraße 1 · A-6342 Niederndorf · T +43 (0) 53 73 6 22 50 - 0 · [email protected] · www.bora.com
The device must not be installed above cooling devices, dishwashers,
stoves, ovens, washing machines or dryers.