adjustments
It’s important to periodically perform a visual check of
the pilot and burner flames. Compare them to the
illustration provided. If any flames appear abnormal,
call a service person.
ADD IMAGE
HERE
36.1
7.0 adjustments
7.1 air shutter
LOG SET AIR SHUTTER
FUEL NG P
GVFL18 9/32” 7/16”
GVFL24 9/32” 7/16”
GVFL30 9/32” 7/16”
The air shutter settings are factory set for most installations. However,
adjustment may be required depending on fuel type, vent performance
and altitude.
Closing the air shutter will cause a more yellow flame, but can lead to
carboning. Opening the air shutter will cause a more blue flame, but
can cause flame lifting from the burner ports. The flame may not appear
yellow immediately; allow 15 to 30 minutes for the final flame colour to be
established.
7.2 flame characteristics
!
WARNING
Carbon can be distributed in surrounding living areas if the air shutter is improperly adjusted.
Failure to keep the primary air opening(s) of the burneer(s) clean may result in sooting and property damage.
La flamme doit envelopper
la sonde de flamme de
3/8" à 1/2"
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
DEXEN EI 2-WAY PILOT
DEXEN EI
ODS - MILLIVOLT
3/8” - 1/2”
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
3/8” - 1/2”
(9.5mm - 12.7mm)
La flamme doit envelopper
la thermocouple de 3/8" à
1/2"
(9.5mm - 12.7mm)
PSE THERMOCOUPLE
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
Flame sensor
SIT ELECTRONIC IGNITION
3/8” - 1/2”
(9.5mm - 12.7mm)
3/8” - 1/2”
(9.5mm - 12.7mm)
3/8” - 1/2”
(9.5mm - 12.7mm)
3/8” - 1/2”
(9.5mm - 12.7mm)
La flamme doit envelopper
la sonde de flamme de
3/8" à 1/2"
(9.5mm - 12.7mm)
3/8” - 1/2”
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple &
thermopile
3/8” - 1/2”
(9.5mm - 12.7mm)
La flamme doit
envelopper la
thermocouple et
thermopile
de 3/8" à 1/2"
(9.5mm - 12.7mm)
SIT MILLIVOLT
3/8” - 1/2”
(9.5mm - 12.7mm)
Flame must envelop
upper
3/8" to 1/2"
(12.7mm - 9.5mm) of
thermocouple
La flamme doit envelopper
la thermocouple de 3/8" à
1/2"
(9.5mm - 12.7mm)
PSE LONG SENSOR
3/8” - 1/2”
(9.5mm - 12.7mm)
7.3 flame height adjustment
The adjustment is made by turning the Hi/Lo knob. The “Hi” setting corresponds to the maximum pressure to the
burner and “Lo” corresponds to the minimum pressure. Actuation of this knob is independent from the actuation
of the ON/OFF control.
Hi / Lo Knob