Masterforce 9001042 10-Gallon 225 PSI Portable Jobsite Air Tank

User Manual - Page 7

For 9001042.

PDF File Manual, 11 pages, Read Online | Download pdf file

9001042 photo
Loading ...
Loading ...
Loading ...
7
OPERATION INSTRUCTIONS
(1) Close the air cock.Fig 4)
(2) Slowly open the drain valve and completely release tank pressure.
(3) Disconnect the air hose from the air plug and quick couplers.
(4) Close the drain valve.(Fig 6)
3. Disconnecting
Risk of serious eye injury from moisture and debris. Always wear ANSI Z87.1 safety
goggles.
High pressure air could result in death or serious injury. Shut off unit, unplug and
release air pressure prior to servicing.
High pressure air containning water condensation could result in minor or result in
minor or moderate injury. Do not spray at any person.
WARNING:
WARNING:
WARNING:
2. Adjustment of outlet pressure
Only one outlet's pressure is regulated (see fig 4). Adjust the outlet pressure to the required level by
turning the knob of the pressure regulator clockwise to increase the outlet pressure and counter
clockwise to decrease it. Tool gauge is provided to show when the required pressure is reached.
When adjusting the pressure, check and make sure that tank gauge for the tank has the pressure level
that is higher than that of the pressure to be adjusted.It is also imperative that you make adjustment by
slowly starting up the pressure from the level that is lower than the pressure to be adjusted.
Fig 4
Air Cock
only this outlet's pressure
is regulated
OFF
ON
Loading ...
Loading ...
Loading ...