Napoleon B46NTRE Ascent 46

User Manual - Page 27

For B46NTRE.

PDF File Manual, 148 pages, Read Online | Download pdf file

B46NTRE photo
Loading ...
Loading ...
Loading ...
EN
W415-2370 / D / 12.09.20
27
rough framing
* See "venting" section.
REAR VENT
REAR EXIT ENCLOSURE
The appliance requires a minimum enclosure height of 41 5/8" (105.7cm). For temperature requirements, the
enclosure space around and above the appliance must be left unobstructed.
24 1/8"
[61.3cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
7”
[178mm]
24"
[61cm]
MINIMUM
PLUS RISE*
COMBUSTIBLE
NON-COMBUSTIBLE
1"
[25mm]
3"
[76mm]
BRICK
0” (0MM) IF
NON-COMBUSTIBLE
FINISHING IS USED
SUCH AS BRICK
AND STONE.
44"
[111.8cm]
10"-20"
[254mm-508mm]
VENT RUN
14 1/2"
[36.8cm]
41 5/8"
[105.7cm]
MINIMUM
1"-10"
[25mm-254mm]
VENT RUN
34 5/8"
[87.9cm]
9 3/8"
[238mm]
For rear vent termination not exceeding 10" (254mm) of horizontal vent run.
24 1/8"
(61.3CM)
MINIMUM PLUS
RISE*
The vent shield must extend the full depth of the combustible wall. It can be cut to suit depths less than 8 1/2"
(216mm).
note:
Loading ...
Loading ...
Loading ...