Technical Data
9.1 Cylinder heat exchanger pressure drop
Figure 16: Heat exchanger pressure drop for 0.8m² and 1.1m² coils
0.8m
2
Coil Pressure Drop
0
10000
20000
30000
40000
50000
60000
70000
80000
90000
100000
0.0 0.5 1.0 1.5 2.0 2.5 3.0
Flow Rate (m
3
/h)
Pressure Drop (Pa)