Installation
5.7.3.2 Solar Sensor Connection Boost Immersion (direct x 1, indirect N/A)
Step 1: Access the sensor mounting plate. To do this remove the immersion cover
plate (A) by removing the fixing screw and insulation foam (B) to access the sensor
mounting plate (C). Remove the M5 fixing screws.
Step 2: The sensor mounting plate will have a vacant slot for the solar probe. Slide the
solar probe into place as shown (D).