ISSUE: 1 190418
For domestic household use only.
INSTRUCTION MANUAL
Models: 10/12/14, E and EL
compliant with the Low Voltage Directive 2014/35/EU, the EMC Directive 2014/30/EU and the RoHS Directive 2011/65/EU.

NB These symbols on your device mean:
• This appliance is lled with Propane gas R290. Follow strictly the manufacturer’s
instruction concerning use and repairs!
• Before using this appliance, you must carefully read the entire instruction manual.
• Do not install, operate or store the device in a room with a oor area smaller than
4m² for 10L/12L models, and 7m² for 14L models.
• Repairs must be performed based on the recommendations from the manufacturing
company.
SPECIFIC SAFETY NOTES RELATING TO REFRIGERANT R290:
• ENVIRONMENTAL INFORMATION: This unit contains uorinated greenhouse gas
covered by the Kyoto Protocol.
• This appliance contains the refrigerant R290.
• R290 is a refrigerant that complies with European ecological standards; nevertheless,
it is recommended not to pierce the cooling circuit of the machine. At the end of
its useful life, deliver the appliance to a special waste collection center for disposal.
• GWP (Global Warming Potential) R290 = 3.
• If the appliance is installed, operated or stored in a non-ventilated area, the room
must be designed to prevent the accumulation of refrigerant leaks resulting in a
risk of re or explosion due to ignition of the refrigerant caused by electric heaters,
stoves, or other sources of ignition.
• When defrosting and cleaning the appliance, do not use any tools other than those
recommended by the manufacturing company.
• The appliance must be placed in an area without any continuous sources of ignition
(for example: open ames, gas or electrical appliances in operation).
• Do not pierce or burn any of the components of the cooling circuit of the unit. Do
not set light to the unit.
• The appliance must be stored in such a way as to prevent mechanical failure or
damage.
• Appliance must be installed, operated and stored in a room with a oor area larger
than 4m² for 10L/12L models, and 7m² for 14L models.
• Be aware that the refrigerant gases may be odourless, which means you cannot
smell leaks.
• Compliance with national gas regulations must be observed.
• Individuals who operate or work on the refrigerant circuit must have the appropriate
certication issued by an accredited organization that ensures competence in
handling refrigerants according to a specic evaluation recognized by national
associations in the industry.
• Maintenance and repairs that require the assistance of other qualied personnel
must be performed under the supervision of an individual specically qualied in
the use of ammable refrigerants.
• Keep ventilation openings clear of obstruction.
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR
FUTURE REFERENCE. Note also the information presented on the appliance
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/
OR DAMAGE AND MAY INVALIDATE YOUR GUARANTEE
Please read the operating instructions carefully before using your dehumidier for the
rst time and keep them in a safe place.
WARNING – This appliance must not be used in a bathroom.
WARNING – Do not use this appliance in the immediate surroundings of a bath, a
shower or a swimming pool.
•
Never immerse the appliance in water or other liquids.
•
Operate this unit only on a rm, at surface to avoid the risk of water leakage. Ensure
that the unit is kept upright at all times (including during transport and storage). If it
is overturned at any stage it should be left standing upright for 24 hours before use.
•
Do not place on soft, unstable or non-horizontal/angled surfaces.
•
Never operate the appliance if a cable or connector has been damaged, after appliance
malfunction or if the appliance was dropped or is otherwise damaged.
•
If the mains lead is damaged it must only be replaced by the manufacturers service
agent or a similarly qualied person in order to avoid a hazard.
•
Please ask a professional service agent to repair the product. Improper repair may
cause danger to users.
•
Disconnect the appliance from mains power whenever it is not in use, before relocating
it, and before cleaning.
•
Operate the appliance only at the voltage specied on the rating label.
•
Only connect the unit to a properly installed and easily accessible socket so that you
can quickly disconnect the plug if necessary.
•
Do not connect this product to the mains using an extension lead.
•
Do not connect the dehumidier to a multiple socket outlet, which is also being used
for other electrical appliances
•
This dehumidier is only intended for INDOOR RESIDENTIAL applications. This
dehumidier should not be used for commercial or industrial or leisure applications or
in small enclosed spaces.
•
Never use the mains lead as a carrying strap or pulling lead.
•
To avoid a re or electrocution hazard, NEVER put the cord near heat registers,
radiator, stoves or heaters.
•
DO NOT cover cord with carpeting, throw rugs, runners, or similar coverings.
•
DO NOT route cord under furniture or appliances. Take care to position the cord away
from trac areas and where it will not be a tripping hazard.
•
DO NOT COVER. Never cover or obstruct in any way the outlet at the top of the
dehumidier or the air inlet slots at the rear of the dehumidier.
•
Only operate this appliance with a minimum of 50cm clearance all around i.e. away
from walls, furniture and overhanging objects such as curtains or a shelf.
3
2

NB These symbols on your device mean:
• This appliance is lled with Propane gas R290. Follow strictly the manufacturer’s
instruction concerning use and repairs!
• Before using this appliance, you must carefully read the entire instruction manual.
• Do not install, operate or store the device in a room with a oor area smaller than
4m² for 10L/12L models, and 7m² for 14L models.
• Repairs must be performed based on the recommendations from the manufacturing
company.
SPECIFIC SAFETY NOTES RELATING TO REFRIGERANT R290:
• ENVIRONMENTAL INFORMATION: This unit contains uorinated greenhouse gas
covered by the Kyoto Protocol.
• This appliance contains the refrigerant R290.
• R290 is a refrigerant that complies with European ecological standards; nevertheless,
it is recommended not to pierce the cooling circuit of the machine. At the end of
its useful life, deliver the appliance to a special waste collection center for disposal.
• GWP (Global Warming Potential) R290 = 3.
• If the appliance is installed, operated or stored in a non-ventilated area, the room
must be designed to prevent the accumulation of refrigerant leaks resulting in a
risk of re or explosion due to ignition of the refrigerant caused by electric heaters,
stoves, or other sources of ignition.
• When defrosting and cleaning the appliance, do not use any tools other than those
recommended by the manufacturing company.
• The appliance must be placed in an area without any continuous sources of ignition
(for example: open ames, gas or electrical appliances in operation).
• Do not pierce or burn any of the components of the cooling circuit of the unit. Do
not set light to the unit.
• The appliance must be stored in such a way as to prevent mechanical failure or
damage.
• Appliance must be installed, operated and stored in a room with a oor area larger
than 4m² for 10L/12L models, and 7m² for 14L models.
• Be aware that the refrigerant gases may be odourless, which means you cannot
smell leaks.
• Compliance with national gas regulations must be observed.
• Individuals who operate or work on the refrigerant circuit must have the appropriate
certication issued by an accredited organization that ensures competence in
handling refrigerants according to a specic evaluation recognized by national
associations in the industry.
• Maintenance and repairs that require the assistance of other qualied personnel
must be performed under the supervision of an individual specically qualied in
the use of ammable refrigerants.
• Keep ventilation openings clear of obstruction.
IMPORTANT
THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR
FUTURE REFERENCE. Note also the information presented on the appliance
CAUTION: FAILURE TO FOLLOW THESE INSTRUCTIONS MAY CAUSE INJURY AND/
OR DAMAGE AND MAY INVALIDATE YOUR GUARANTEE
Please read the operating instructions carefully before using your dehumidier for the
rst time and keep them in a safe place.
WARNING – This appliance must not be used in a bathroom.
WARNING – Do not use this appliance in the immediate surroundings of a bath, a
shower or a swimming pool.
•
Never immerse the appliance in water or other liquids.
•
Operate this unit only on a rm, at surface to avoid the risk of water leakage. Ensure
that the unit is kept upright at all times (including during transport and storage). If it
is overturned at any stage it should be left standing upright for 24 hours before use.
•
Do not place on soft, unstable or non-horizontal/angled surfaces.
•
Never operate the appliance if a cable or connector has been damaged, after appliance
malfunction or if the appliance was dropped or is otherwise damaged.
•
If the mains lead is damaged it must only be replaced by the manufacturers service
agent or a similarly qualied person in order to avoid a hazard.
•
Please ask a professional service agent to repair the product. Improper repair may
cause danger to users.
•
Disconnect the appliance from mains power whenever it is not in use, before relocating
it, and before cleaning.
•
Operate the appliance only at the voltage specied on the rating label.
•
Only connect the unit to a properly installed and easily accessible socket so that you
can quickly disconnect the plug if necessary.
•
Do not connect this product to the mains using an extension lead.
•
Do not connect the dehumidier to a multiple socket outlet, which is also being used
for other electrical appliances
•
This dehumidier is only intended for INDOOR RESIDENTIAL applications. This
dehumidier should not be used for commercial or industrial or leisure applications or
in small enclosed spaces.
•
Never use the mains lead as a carrying strap or pulling lead.
•
To avoid a re or electrocution hazard, NEVER put the cord near heat registers,
radiator, stoves or heaters.
•
DO NOT cover cord with carpeting, throw rugs, runners, or similar coverings.
•
DO NOT route cord under furniture or appliances. Take care to position the cord away
from trac areas and where it will not be a tripping hazard.
•
DO NOT COVER. Never cover or obstruct in any way the outlet at the top of the
dehumidier or the air inlet slots at the rear of the dehumidier.
•
Only operate this appliance with a minimum of 50cm clearance all around i.e. away
from walls, furniture and overhanging objects such as curtains or a shelf.
3
2

•
Children aged from 3 years and less than 8 years shall only switch on/o the appliance
provided that it has been placed or installed in its intended normal operating position
and they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and clean the appliance or perform user
maintenance.
•
Children of less than 3 years should be kept away unless continuously supervised.
•
To prevent spillage, empty the water tank before lifting or relocating the appliance.
•
Do not tip the appliance to any side as escaping water could damage the appliance.
•
Do not use in cabinet, closet, boats, caravans or similar locations.
•
Leave the unit to stand for 12 hours before connecting to the mains supply after
transport or when it has been titled (ex. During cleaning).
•
Only use the unit in the upright position on a at level surface
•
Do not use the unit in a potentially explosive environment containing combustible
liquids, gases or dusts.
•
Do not use the appliance in the vicinity of ammable or explosive substances or fuels.
Never use any paint, cleaning sprays, anti-insect sprays or similar near the unit; this
could damage or deform the plastic or cause electrical damage.
•
Never leave this product running unsupervised.
•
WARNING: Never leave water in the reservoir when the appliance is not in use,
microorganisms can grow in stagnant water, the water tank should be emptied and
cleaned regularly and properly. Empty the tank, clean and dry it when not in use and
before putting into storage.
•
CAUTION: Clean and empty the water tank at least every third day. Empty the water
tank and clean it with fresh tap water or mild detergent. Remove any scale, deposits,
or lm that has formed on the sides of the water tank or on interior surfaces using
soft non-abrasive cleaning agents (such as washing up liquid), wipe all surfaces dry
on completion.
•
WARNING – The water collected in the tank is must never be used for drinking, it is
not suitable for human, bird or animal consumption.
•
Be aware that high humidity levels may encourage the growth of biological organisms
in the environment.
•
Monitor the area around the dehumidier to ensure there is no damp or wet. Do not
allow absorbent materials, such as carpeting, drapes, or tablecloths to become damp.
•
When the unit stops, you have to wait for 3 minutes before you can restart the unit to
protect the compressor from damage
•
Air inlet lter must be cleaned regularly to ensure correct operation and to avoid
damage to the appliance.
•
Never operate the product without the lter
•
WARNING: To avoid danger of suocation please remove all packaging materials
particularly plastic and EPS and keep these away from vulnerable people, children
and babies.
•
WARNING: To avoid the risk of accidental strangulation from the supply cord all
children and vulnerable people must be supervised when in the vicinity of the product
whether it is working or not.
•
IMPORTANT: Do not use this unit where the ambient temperature is lower than 5
o
C,
otherwise the evaporating coil will ice up heavily and this will aect the performance
of the product and potentially cause a malfunction.
•
NEVER drop or insert any object into any openings.
•
Do not use the appliance in locations where paint, petrol or other ammable liquids
are used or stored.
•
Do not use bug sprays or other ammable cleansers/vapour sprays on or around
the unit.
•
Always switch o the unit and take the plug out of the socket.
- If you are not using the unit
- Before you clean or carry out maintenance on the unit
- If a fault occurs
- In the event of an electrical storm.
5
4

•
Children aged from 3 years and less than 8 years shall only switch on/o the appliance
provided that it has been placed or installed in its intended normal operating position
and they have been given supervision or instruction concerning use of the appliance
in a safe way and understand the hazards involved. Children aged from 3 years and
less than 8 years shall not plug in, regulate and clean the appliance or perform user
maintenance.
•
Children of less than 3 years should be kept away unless continuously supervised.
•
To prevent spillage, empty the water tank before lifting or relocating the appliance.
•
Do not tip the appliance to any side as escaping water could damage the appliance.
•
Do not use in cabinet, closet, boats, caravans or similar locations.
•
Leave the unit to stand for 12 hours before connecting to the mains supply after
transport or when it has been titled (ex. During cleaning).
•
Only use the unit in the upright position on a at level surface
•
Do not use the unit in a potentially explosive environment containing combustible
liquids, gases or dusts.
•
Do not use the appliance in the vicinity of ammable or explosive substances or fuels.
Never use any paint, cleaning sprays, anti-insect sprays or similar near the unit; this
could damage or deform the plastic or cause electrical damage.
•
Never leave this product running unsupervised.
•
WARNING: Never leave water in the reservoir when the appliance is not in use,
microorganisms can grow in stagnant water, the water tank should be emptied and
cleaned regularly and properly. Empty the tank, clean and dry it when not in use and
before putting into storage.
•
CAUTION: Clean and empty the water tank at least every third day. Empty the water
tank and clean it with fresh tap water or mild detergent. Remove any scale, deposits,
or lm that has formed on the sides of the water tank or on interior surfaces using
soft non-abrasive cleaning agents (such as washing up liquid), wipe all surfaces dry
on completion.
•
WARNING – The water collected in the tank is must never be used for drinking, it is
not suitable for human, bird or animal consumption.
•
Be aware that high humidity levels may encourage the growth of biological organisms
in the environment.
•
Monitor the area around the dehumidier to ensure there is no damp or wet. Do not
allow absorbent materials, such as carpeting, drapes, or tablecloths to become damp.
•
When the unit stops, you have to wait for 3 minutes before you can restart the unit to
protect the compressor from damage
•
Air inlet lter must be cleaned regularly to ensure correct operation and to avoid
damage to the appliance.
•
Never operate the product without the lter
•
WARNING: To avoid danger of suocation please remove all packaging materials
particularly plastic and EPS and keep these away from vulnerable people, children
and babies.
•
WARNING: To avoid the risk of accidental strangulation from the supply cord all
children and vulnerable people must be supervised when in the vicinity of the product
whether it is working or not.
•
IMPORTANT: Do not use this unit where the ambient temperature is lower than 5
o
C,
otherwise the evaporating coil will ice up heavily and this will aect the performance
of the product and potentially cause a malfunction.
•
NEVER drop or insert any object into any openings.
•
Do not use the appliance in locations where paint, petrol or other ammable liquids
are used or stored.
•
Do not use bug sprays or other ammable cleansers/vapour sprays on or around
the unit.
•
Always switch o the unit and take the plug out of the socket.
- If you are not using the unit
- Before you clean or carry out maintenance on the unit
- If a fault occurs
- In the event of an electrical storm.
5
4

weather outdoors
Near water If the power cable
wires are frayed or cut
Where small children
may be left unattended
lead may become
overload
Where there is risk
Where the power
cable may be
damaged
On a slope or
uneven surface
Where it may be
damaged by
chemicals
If there is a risk
of water falling on
the unit
Where there is a risk
of interference by
foreign objects
This product is not
made for DIY repair
Model no. 10L 12L 14L
C, 80%
10L/day
12L/day 14L/day
3.3L/day 4.4L/day 4.7L/day
1.5L/day 1.7L/day 1.5L/day
Working range 5 ~ 32
C
Water tank 2.5 L
N.W. 10.5 kg 11 kg 11.5 kg
Standard Ampere consumption 1.5A 1.5A 1.4A
130M3/h
Compressor Reciprocating
Refrigerant
3
0.035kg 0.045kg 0.065kg
0.000105 tonnes 0.00012 tonnes
Hermetically sealed system.
Hedge End, Southampton SO30 2DF
280W
0.35W 0.35W 0.35W
• The data marked with * may vary for technical reasons. For greater precision, please
refer to the rating label placed on the product.
• Test condition for data in our rating label is as per safety regulation: EN 60335-2-40
heat, this is normal and may potentially raise the room temperature.
7
6

weather outdoors
Near water If the power cable
wires are frayed or cut
Where small children
may be left unattended
lead may become
overload
Where there is risk
Where the power
cable may be
damaged
On a slope or
uneven surface
Where it may be
damaged by
chemicals
If there is a risk
of water falling on
the unit
Where there is a risk
of interference by
foreign objects
This product is not
made for DIY repair
Model no. 10L 12L 14L
C, 80%
10L/day
12L/day 14L/day
3.3L/day 4.4L/day 4.7L/day
1.5L/day 1.7L/day 1.5L/day
Working range 5 ~ 32
C
Water tank 2.5 L
N.W. 10.5 kg 11 kg 11.5 kg
Standard Ampere consumption 1.5A 1.5A 1.4A
130M3/h
Compressor Reciprocating
Refrigerant
3
0.035kg 0.045kg 0.065kg
0.000105 tonnes 0.00012 tonnes
Hermetically sealed system.
Hedge End, Southampton SO30 2DF
280W
0.35W 0.35W 0.35W
• The data marked with * may vary for technical reasons. For greater precision, please
refer to the rating label placed on the product.
• Test condition for data in our rating label is as per safety regulation: EN 60335-2-40
heat, this is normal and may potentially raise the room temperature.
7
6

How It Works
This product is a dehumidier. It controls relative humidity by passing the air through
the unit, forcing the excess moisture to condensate over the cooling elements.
Contact with this cold surface causes the moisture in the air to condense. This condensed
water then drains safely into the water tank. The dried air then passes through the
condenser where it is slightly warmed and re-enters the room at a slightly elevated
temperature.
Where To Position
Excess moisture will travel throughout your home, in the same way that cooking smells
waft to every room in the house. For this reason, the dehumidier should be positioned,
so that it can draw this moist air towards it from all over the home.
Alternatively, if you have a serious problem in one area you can begin by positioning
the dehumidier close to this area and later moving it to a more central point.
When positioning the dehumidier, ensure that it is placed on a level surface and
that there is a minimum of 30 cm (12”) of space on either side of the unit to allow for
ecient airow.
This dehumidier is tted with castors for extra mobility, if you move the unit, it should
rst be switched o and the water tank emptied. We do not recommend the use of an
extension lead, so please try to ensure that the unit is suciently close to a xed mains
socket.
When the dehumidier is in operation, outside doors and windows should be closed
for most eective and ecient operation.
Compressor
Fan
Water Tank
Motor
Evaporator
Condenser
Air Outlet
Air Inlet
The Active Carbon Filter is used for capturing the smaller particles of dust suspended
in the air and for absorbing formaldehyde, benzene and other noxious gases. It has a
limited life span and should be replaced when it becomes obviously dirty/discoloured.
The useful life expectancy of the lter will depend on the conditions where it is used
and the type of use/amount of use the product is subjected to.
Parts
Accessories
Active Carbon Filter
Filter
Inlet
Water Tank
Humidity light
selected model
Outlet
Carry handles
Castors
Spout For
Continous
Drainage
9
8

How It Works
This product is a dehumidier. It controls relative humidity by passing the air through
the unit, forcing the excess moisture to condensate over the cooling elements.
Contact with this cold surface causes the moisture in the air to condense. This condensed
water then drains safely into the water tank. The dried air then passes through the
condenser where it is slightly warmed and re-enters the room at a slightly elevated
temperature.
Where To Position
Excess moisture will travel throughout your home, in the same way that cooking smells
waft to every room in the house. For this reason, the dehumidier should be positioned,
so that it can draw this moist air towards it from all over the home.
Alternatively, if you have a serious problem in one area you can begin by positioning
the dehumidier close to this area and later moving it to a more central point.
When positioning the dehumidier, ensure that it is placed on a level surface and
that there is a minimum of 30 cm (12”) of space on either side of the unit to allow for
ecient airow.
This dehumidier is tted with castors for extra mobility, if you move the unit, it should
rst be switched o and the water tank emptied. We do not recommend the use of an
extension lead, so please try to ensure that the unit is suciently close to a xed mains
socket.
When the dehumidier is in operation, outside doors and windows should be closed
for most eective and ecient operation.
Compressor
Fan
Water Tank
Motor
Evaporator
Condenser
Air Outlet
Air Inlet
The Active Carbon Filter is used for capturing the smaller particles of dust suspended
in the air and for absorbing formaldehyde, benzene and other noxious gases. It has a
limited life span and should be replaced when it becomes obviously dirty/discoloured.
The useful life expectancy of the lter will depend on the conditions where it is used
and the type of use/amount of use the product is subjected to.
Parts
Accessories
Active Carbon Filter
Filter
Inlet
Water Tank
Humidity light
selected model
Outlet
Carry handles
Castors
Spout For
Continous
Drainage
9
8



Drainage
While the water tank is full, the compressor will stop for self-protection and the water
full indicator light will turn red.
To move the water tank, pull it out squarely from the unit.
After empting the water tank, place the water tank carefully back into its location into
space. The tank must be properly located in order for the ‘water full’ light to go out
and for your dehumidier to start operating again.
Please note, if the water tank has not been positioned/located correctly, the water full
indicator will stay red and the product will not operate.
CONTINUOUS DRAINAGE
When the dehumidier is operated at very high humidity levels, the water tank will
require more frequent emptying. In this situation, it may be more convenient to set the
unit up for continuous drainage, this can be done as follows;
1 . P u l l o u t t h e w a t e r t a n k .
2. Connect a water drain tube of inner
diameter 11 mm to the drain spout
connection outlet at the top of the
tank location area.
* Please note, the water tube is not supplied
with the unit.
3. Ensure the drain tube is xed properly
and that water will always drain away
freely through the tube (the drain
point/open end of the tube must be
at a lower height than the drain outlet
from the product).
Note! In very cold weather conditions,
precautions should be taken to prevent the
water tube from freezing.
4. Put the water tank back to its position.
Spout connection
for continuous
drainage
Water drain tube
with 11mm internal
diameter
Always unplug the unit from the mains before carrying out any maintenance or cleaning
of the unit.
CLEANING THE BODY
Use a soft damp cloth to wipe the unit clean.
Don’t ever use volatile chemicals, gasoline, detergents, chemically treated clothes, or
other cleansing solutions. These all could possibly damage the enclosure.
CLEANING THE FILTER
This dehumidier is equipped with 2 lters.
The plastic dust lter is washable and should be cleaned approximately every 2 weeks
when in use (see instruction below).
The active carbon lter is not washable its life span is variable and depends on the
ambient conditions where the unit is used. The lter should be checked periodically
and replaced if necessary.
WASHING THE PLASTIC DUST FILTER
•
Remove the anti-dust lter and separate the active carbon lter (not washable)
and set it aside carefully.
•
Use a vacuum cleaner or tap the plastic air lter lightly for easy cleaning. If the
lter is particularly dirty, use warm water with a small amount of medium strength
detergent to rinse the lter.
• Allow it to dry naturally and make sure the lter is completely dry before replacing.
• Do not expose the lter to sunlight.
STORAGE
If not using the unit for an extended period of time. Please:
• Turn the unit o, unplug and take care of the mains lead & plug.
• Completely empty the water tank and clean it thoroughly and wipe it dry.
•
Cover the unit and store it upright in a location where it will not receive direct sunlight.
NB- Prolonged exposure to direct sunlight will discolour the enclosure.
Maintenance
Anti-Dust
Filter
Active Carbon
Filter
Air Inlet
13
12

Drainage
While the water tank is full, the compressor will stop for self-protection and the water
full indicator light will turn red.
To move the water tank, pull it out squarely from the unit.
After empting the water tank, place the water tank carefully back into its location into
space. The tank must be properly located in order for the ‘water full’ light to go out
and for your dehumidier to start operating again.
Please note, if the water tank has not been positioned/located correctly, the water full
indicator will stay red and the product will not operate.
CONTINUOUS DRAINAGE
When the dehumidier is operated at very high humidity levels, the water tank will
require more frequent emptying. In this situation, it may be more convenient to set the
unit up for continuous drainage, this can be done as follows;
1 . P u l l o u t t h e w a t e r t a n k .
2. Connect a water drain tube of inner
diameter 11 mm to the drain spout
connection outlet at the top of the
tank location area.
* Please note, the water tube is not supplied
with the unit.
3. Ensure the drain tube is xed properly
and that water will always drain away
freely through the tube (the drain
point/open end of the tube must be
at a lower height than the drain outlet
from the product).
Note! In very cold weather conditions,
precautions should be taken to prevent the
water tube from freezing.
4. Put the water tank back to its position.
Spout connection
for continuous
drainage
Water drain tube
with 11mm internal
diameter
Always unplug the unit from the mains before carrying out any maintenance or cleaning
of the unit.
CLEANING THE BODY
Use a soft damp cloth to wipe the unit clean.
Don’t ever use volatile chemicals, gasoline, detergents, chemically treated clothes, or
other cleansing solutions. These all could possibly damage the enclosure.
CLEANING THE FILTER
This dehumidier is equipped with 2 lters.
The plastic dust lter is washable and should be cleaned approximately every 2 weeks
when in use (see instruction below).
The active carbon lter is not washable its life span is variable and depends on the
ambient conditions where the unit is used. The lter should be checked periodically
and replaced if necessary.
WASHING THE PLASTIC DUST FILTER
•
Remove the anti-dust lter and separate the active carbon lter (not washable)
and set it aside carefully.
•
Use a vacuum cleaner or tap the plastic air lter lightly for easy cleaning. If the
lter is particularly dirty, use warm water with a small amount of medium strength
detergent to rinse the lter.
• Allow it to dry naturally and make sure the lter is completely dry before replacing.
• Do not expose the lter to sunlight.
STORAGE
If not using the unit for an extended period of time. Please:
• Turn the unit o, unplug and take care of the mains lead & plug.
• Completely empty the water tank and clean it thoroughly and wipe it dry.
•
Cover the unit and store it upright in a location where it will not receive direct sunlight.
NB- Prolonged exposure to direct sunlight will discolour the enclosure.
Maintenance
Anti-Dust
Filter
Active Carbon
Filter
Air Inlet
13
12

Trouble shooting
THE UNIT DOES NOT OPERATE:
• Is the unit plugged in?
• Is the house electricity on?
•
Is the room temperature below 5C or above 32C? If so, then it is out of the working
range of the unit.
• Ensure the ON/OFF switch is turned on.
• Check the water tank is located properly in the unit and it is not full.
• Make sure the air inlet and outlet are not obstructed.
THE UNIT SEEMS TO DO NOTHING:
•
• Is the air intake or outlet blocked?
• Is the room humidity already quite low?
THE UNIT SEEMS TO DO LITTLE:
• Are too many windows or doors open?
• Is there something in the room producing lots of humidity?
THE UNIT IS TOO NOISY:
• Check whether the unit is sitting on a level surface.
THE UNIT IS LEAKING:
•
• Check that the water tank is not damaged.
Recycling: For electrical products sold within the European
Community. At the end of the electrical products useful life it
should not be disposed of with household waste. Please recycle
where facilities exist.Check with your Local Authority or retailer
for recycling advice in your country.
What does a Dimplex Warranty cover?
is found to be defective due to faulty materials or workmanship within the Warranty
Your product is under warranty for 1 year from the date of purchase or the date of
the UK and Ireland.
your information and proof of purchase we will contact you to make the necessary
arrangements.
to repair your product. However, we will contact you for agreement to any charges
before any chargeable service is carried out.
What is not covered by a Dimplex Warranty?
Normal wear and tear including parts that might wear out over time or consumables,
Not due to faulty materials or workmanship or which is due to circumstances outside
normal domestic household purposes in the country where it was purchased.
limited to any failure to use it in accordance with the Operating Instructions supplied
with the product.Caused by any failure to assemble, install clean and maintain your
Warranty
15
14

Trouble shooting
THE UNIT DOES NOT OPERATE:
• Is the unit plugged in?
• Is the house electricity on?
•
Is the room temperature below 5C or above 32C? If so, then it is out of the working
range of the unit.
• Ensure the ON/OFF switch is turned on.
• Check the water tank is located properly in the unit and it is not full.
• Make sure the air inlet and outlet are not obstructed.
THE UNIT SEEMS TO DO NOTHING:
•
• Is the air intake or outlet blocked?
• Is the room humidity already quite low?
THE UNIT SEEMS TO DO LITTLE:
• Are too many windows or doors open?
• Is there something in the room producing lots of humidity?
THE UNIT IS TOO NOISY:
• Check whether the unit is sitting on a level surface.
THE UNIT IS LEAKING:
•
• Check that the water tank is not damaged.
Recycling: For electrical products sold within the European
Community. At the end of the electrical products useful life it
should not be disposed of with household waste. Please recycle
where facilities exist.Check with your Local Authority or retailer
for recycling advice in your country.
What does a Dimplex Warranty cover?
is found to be defective due to faulty materials or workmanship within the Warranty
Your product is under warranty for 1 year from the date of purchase or the date of
the UK and Ireland.
your information and proof of purchase we will contact you to make the necessary
arrangements.
to repair your product. However, we will contact you for agreement to any charges
before any chargeable service is carried out.
What is not covered by a Dimplex Warranty?
Normal wear and tear including parts that might wear out over time or consumables,
Not due to faulty materials or workmanship or which is due to circumstances outside
normal domestic household purposes in the country where it was purchased.
limited to any failure to use it in accordance with the Operating Instructions supplied
with the product.Caused by any failure to assemble, install clean and maintain your
Warranty
15
14

Terms and Conditions
The Dimplex Warranty is valid for 1 calendar year, plus 2 if registered, from the date of
purchase of your Dimplex product from a recognised retailer in the country of purchase
and use, or the date of delivery of the product if later, always provided the original
receipt has been retained and is produced as proof of purchase.
You must provide to Dimplex or its authorised agents on request the original receipt
as proof of purchase and - if required by Dimplex - proof of delivery. If you are unable
to provide this documentation, you will be required to pay for any repair work required.
Any repair work under the Dimplex Warranty will be carried out by Dimplex or its
authorised dealer(s) and any parts that are replaced will become the property of Dimplex.
Any repairs performed under the Dimplex Warranty will not extend the Warranty Period.
Any replacement of your Dimplex product by Dimplex during the Warranty Period will
start the 3 year Warranty Period afresh from the date of delivery of the replacement
Dimplex product to you. (*Please keep original online warranty registration email and
sales receipt for your original purchase as proof of the additional 2 years, in case of
the unlikely event you experience an issue).
The Dimplex Warranty does not entitle you to recovery of any indirect or consequential
loss or damage including but not limited to loss or damage to any other property.
The Dimplex Warranty is in addition to your statutory rights as a consumer and your
statutory rights are not aected by this Dimplex Warranty.
Contact Dimplex A brand of the GDC Group Limited, trading as Glen Dimplex Heating & Ventilation
If you have any questions about what the Dimplex Warranty covers and does not cover
or how to claim under the Dimplex Warranty, please contact us:
GDHV, Grange Drive, Hedge End, Southampton SO30 2DF
Telephone: 0344 879 3588
Email: customer.services@glendimplex.com
Visit: www.dimplex.co.uk
[c] Glen Dimplex
All rights reserved. Material contained in this publication may not be reproduced in whole or in part,
without prior permission in writing of Glen Dimplex.
17
16

Terms and Conditions
The Dimplex Warranty is valid for 1 calendar year, plus 2 if registered, from the date of
purchase of your Dimplex product from a recognised retailer in the country of purchase
and use, or the date of delivery of the product if later, always provided the original
receipt has been retained and is produced as proof of purchase.
You must provide to Dimplex or its authorised agents on request the original receipt
as proof of purchase and - if required by Dimplex - proof of delivery. If you are unable
to provide this documentation, you will be required to pay for any repair work required.
Any repair work under the Dimplex Warranty will be carried out by Dimplex or its
authorised dealer(s) and any parts that are replaced will become the property of Dimplex.
Any repairs performed under the Dimplex Warranty will not extend the Warranty Period.
Any replacement of your Dimplex product by Dimplex during the Warranty Period will
start the 3 year Warranty Period afresh from the date of delivery of the replacement
Dimplex product to you. (*Please keep original online warranty registration email and
sales receipt for your original purchase as proof of the additional 2 years, in case of
the unlikely event you experience an issue).
The Dimplex Warranty does not entitle you to recovery of any indirect or consequential
loss or damage including but not limited to loss or damage to any other property.
The Dimplex Warranty is in addition to your statutory rights as a consumer and your
statutory rights are not aected by this Dimplex Warranty.
Contact Dimplex A brand of the GDC Group Limited, trading as Glen Dimplex Heating & Ventilation
If you have any questions about what the Dimplex Warranty covers and does not cover
or how to claim under the Dimplex Warranty, please contact us:
GDHV, Grange Drive, Hedge End, Southampton SO30 2DF
Telephone: 0344 879 3588
Email: customer.services@glendimplex.com
Visit: www.dimplex.co.uk
[c] Glen Dimplex
All rights reserved. Material contained in this publication may not be reproduced in whole or in part,
without prior permission in writing of Glen Dimplex.
17
16

Customer Helpline: 0344 879 3588
aftersales@dimplex.co.uk
www.dimplex.co.uk
Glen Dimplex Heating and Ventilation
Millbrook House, Grange Drive, Hedge End, Southampton, SO30 2DF
© Glen Dimplex. All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior
permission in writing of Glen Dimplex
These products fully comply with all current European Safety Standard requirements for Dehumidifiers, and, are fully
compliant with the Low Voltage Directive 2014/35/EU, the EMC Directive 2014/30/EU and the RoHS Directive 2011/65/EU.