10 HUSKY INSTRUCTION MANUAL
SETTING THE THERMOSTAT – COUNTERTOP MODELS
The controller is positioned on the external back wall of the appliance. The
settings 1 (MIN) – 5 (MAX) regulate the interior temperature.
Setting 1 (or MIN) = lowest setting (warmest internal temperature)
Setting 5 (or MAX) = highest setting (coldest internal temperature).
SETTING THE THERMOSTAT – UNDERCOUNTER MODELS
The controller is positioned on the interior
side wall of the appliance. Thermostat “0”
position indicates the appliance is turned off
although power is still connected. By turning
the thermostat dial clockwise, the appliance
will turn on automa ti cally. The settings 1
(MIN) – 7 (MAX) regulate the interior
temperature of the appliance.
Setting 0 = Off (not operating)
Setting 1 (or MIN) = lowest setting (warmest internal temperature)
Setting 7 (or MAX) = highest setting (coldest internal temperature).
CHANGING THE LED LIGHT BULB (where applicable)
Before removing the light bulb, you must unplug the appliance. Failure to do so
may result in electrical shock or personal injury.
Remove the light bulb cover (1) by gently removing the screw (3)
Unscrew the bulb (2) Fit a 1w E14 LED bulb that is the same shape and size
IMPORTANT: replace the light cover to its original position.