Next, remove the access panel by pulling it up and out from the side edge of the panel. Use
caution – the panel edges may be sharp (see Figure 2).
4. Condition 4:
Fan access and installation is through the front lower grille. There is no access to fan through
the hearth.
Fan Installation
CAUTION: Be sure that no wires are pinched
Prior to reinstalling the access panel and the hearth brick, it is advisable to operate the wall
switch on and off to assure fan operation. If the fan does not operate and you are assured that
115 VAC power is present at the receptacle, contact your dealer.
Reinstall the access panel and hearth brick by reversing Step 1.
WARNING: Never contact blower wheels during operation.
Recommended Operating Procedures
Light your fireplace with the fan off. After the fire has been burning for about 30 minutes, turn the fan
on. Heated air should be delivered at the outlet grille.
ATTENTION!
The thermodisc is set to turn on at approximately 120° F and
will shut off at approximately 90° F.
NOTE: Blower will not start
until thermodisc is heated to approximately 120° F.
The thermodisc has been factory tested.
PayandPack.com
Please connect the power cord or any power supply / control wires with this replacemnet blower.
Make sure all wires / leads are connected CORRECTLY before pluging and being switch on.
The GREEN wire (grounding wire) must be connected for safety.
There are two grounding plate pins beside blower fan metal case / cover,
or you can attach grounding wire onto the blower with bolt and nut.
The diagram shown below is for your reference only, please refer to original parts instructions