Durablow MFB004-A UZY5, PUZY5, 26180 Replacement Fireplace Dual Blower Fan Kit for Security, Continental, Napoleon, Lennox, Rotom

User Manual - Page 2

For MFB004-A.

PDF File Manual, 3 pages, Read Online | Download pdf file

MFB004-A photo
Loading ...
note
The black and white wires on the AC box
wiring harness are marked ‘Blower’, ‘Light’
and ‘Aux’. It is important to use the wires
marked ‘Blower’ or the control will not work
correctly.
Page 2
1. Open the bottom louver of the freplace.
2. Place each blower kit into the freplace side opening,
leave a space of 1/8" - 1/4" from the back of the freplace. (See Fig. 2)
3. Install the automatic blower activator (Thermostat) on the side of the frebox.
(the thermostat has a magnetic mount, place it under the firebox)
4. Plug the blower kit into the junction box.
5. Ground both blowers to the back panel using the green screws. (see Fig. 1)
Fig. 2
These blowers require periodic maintenance.
Check the area in front of the blowers and wipe
or vacuum at least once a month during the burn
season.
MAINTENANCE:
The freplace must be electrically connected and grounded in accordance with local codes or in the absence of local
codes, with the current CSA C22.1 Canadian Electrical Code. For U.S.A. installations, follow local codes and the
National Electrical Code ANSI/NFPA No 70.
NOTE:
Installation instructions: