TROUBLESHOOTING
PROBLEM ROOT CAUSE CORRECTIVE ACTION
Unit is not
heating.
The overheat protection has
activated.
Inspect the garage heater and check
that the air inlets and outlets are not
blocked as this may cause overheat
-
ing. Switch off the circuit breaker to
the garage heater for 30 minutes and
allow it to cool down. Turn the power
back on and operate.
The breaker has tripped
Reset the breaker at the fuse panel
and restart the heater
Garage heater
emits a
burning smell
The room temperature has
already reached the set
thermostat temperature
Adjust the temperature setting to
make sure the thermostat
setting temperature is higher than
current room temperature.
During production dust and/
or oil debris gathered on
heating coils.
Make sure the room is well
ventilated. Allow the garage heater to
run until the smell is dissipated.
Check and make sure there
is no combustible material
within 0.9 meters (3 feet) of
the garage heater.
Remove the combustible material
around the garage heater.
This heater must be
mounted at least 8 feet
off the oor, for specic
clearances, please check
the "LOCATING HEATER"
section in the instruction
manual
Relocate the garage heater so there
is enough space between the heater
and adjacent wall and oor.