4
INSTALLATION
OPERATION
The heater is for oor mounting. Place the heater on oor or
other at surface and insert plug into the proper wall outlet.
FLOOR APPLICATION
The heater must be properly installed before it is used.
Set thermostat to its full counterclockwise position. Plug the unit into a properly
grounded 240V outlet. Set the thermostat to the farthest clockwise position. The fan
should come on and the unit will start heating the room. When the room reaches
comfort level, turn the thermostat counterclockwise until the heater turns off.
The heater will cycle automatically around this preset temperature. To increase
temperature, turn the thermostat knob clockwise. To lower temperature, turn the
thermostat counterclockwise. Do not attempt to tamper with the thermostat.
The EG4800DG and EG5600DG garage heaters include
a wall / ceiling mounting bracket. The bracket should be
mounted to a structure that is capable of supporting the
combined weight of the heater and the bracket. Ideally,
the bracket should be secured to a wall stud, roof truss,
or onto a solid block wall using the proper mounting
hardware. The heater should be mounted as close to the
power supply as possible to avoid the use of an extension
cord.
1. Drill two holes in a wall/ceiling, the distance of the
holes should match the bracket.
2. Screw two M10*30 screws (not included) to wall/
ceiling, make sure the bracket is secured.
3. Hang the heater as shown below, secure the heater
to the bracket by inserting a bolt through a washer
(included) into the pre-drilled holes.
4. Secure the bolt with a lock washer and nut (included).
Tighten with a wrench.
WALL OR CEILING MOUNTING