FORM NO. Z2496
REV. D-05/23/2019
PERLICK COLLECTION 24” AND 30”
COLUMN REFRIGERATION
To prevent appliance damage and injury, read these instrucons thoroughly
prior to installaon.
CR SERIES
INSTALLATION
INSTRUCTIONS

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
2 | perlick.com/residential
PRODUCT IDENTIFICATION PLATE
Your product informaon can be found on the product’s
idencaon plate. The idencaon plate for CR24 and CR30
column refrigeraon models is located on the sidewall behind
the toe kick plate. To access the indencaon plate, simply
remove the toe kick plate (grill). The idencaon plate will be
adhered to the right sidewall.
INTRODUCTION
Congratulaons on your purchase of a Perlick Collecon column
refrigeraon appliance. This manual has been prepared to assist
you in the installaon of your column refrigerator, freezer and
wine reserve.
We dedicate considerable me to ensure that our products
provide the highest level of customer sasfacon. We thank
you for selecng Perlick products for your home and assure you
of our connuing interest in your sasfacon.
WARRANTY REGISTRATION
To register your Perlick product, visit our website at
www.perlick.com/RegisterMyPerlick and ll out the form.
Once completed, click on the ‘Submit Warranty Registraon’. Be
sure to register your product immediately upon installaon to
receive the warranty from installaon date instead of shipment
date. If le blank, the date will revert back to shipment date.
CONTENTS
3 Safety Consideraons
4 Prior to Installaon
4 Opening Dimensions (Single and Dual)
5 Niche/Product Dimensions, Installing adjacent to wall
6 Electrical
6 An-p Bracket
6 Installing 90° Hinge Pin
7 Leveling/Alignment
10 Door/Side Panel Informaon
16 Door Panel Installaon/Adjustment
18 Air Flow Divider
18 Door Trim Installaon
19 Compleon - Grill Installaon
20 Toe Kick Clearance
21 Installing Filters

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 3
SAFETY CONSIDERATIONS
IMPORTANT SAFETY INFORMATION
Please review the following safety precauons and read all
instrucons prior to product installaon. Aer the compleon
of installaon, keep these instrucons in a safe place for future
reference.
Please take special care when reading the highlighted
informaon in this guide. This informaon is coded as follows:
DAN Thisindicatesthatahazardoussituaon
mayoccurwheninstruconsarenotfollowed.Itisimperive
thatdireconsinthisguidearefollowedtopreventpossible
serious injury or death.
Thisindicatesasituaonwhereminor
injury,productorcabinetdamagemayoccurifthefollowing
instruconsarenotfollowed.
This highlights informaon that is of
signicant importance.
WARNING
DANGER
!
CAUTION
SAFETY PRECAUTIONS
Please take note of the following safety precauons prior to
moving, unpacking and installing your Perlick column.
DAN Takecarewhenhandling,movingorusing
therefrigeratedcabinettoavoiddamagingtherefrigerant
tubing.Damagingtherefrigeranttubingincreasestheriskof
leakageandcanbedangerous.
Perlickcolumnsweighupto550lbs.Take
specialcarewhenmovingtopreventseriousinjury.
Perlickcolumnsaretopheavy.Itis
importantthatthedoorissecuredclosedunlinstalled.
Installasdirectedtopreventpping.
Donotuseorstoreammableliquids(ie;
gasoline)orvaporsnearappliances.
Inspecttheelectricalcordandplugfor
damage prior to plugging the unit in.
Intheeventthatserviceisneccessary,
repairworkmustbeperformedbyaPerlickauthorized
servicerastominimizetheriskofpossibleigniondue
toincorrectpartsorimproperservice.Workdoneby
unqualiedindividualscouldpotenallybedangerousand
willvoidthewarranty.Componentpartswillbereplaced
withlikecomponentsfromPerlick.
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!
DANGER
!

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
4 | perlick.com/residential
PRIOR TO INSTALLATION
PRIOR TO INSTALLATION
Before beginning installaon, carefully
inspect the cabinet for hidden damage. If damage is discovered,
immediately le a claim with the transportaon company.
Perlick is not responsible for damage in transit.
When moving the unit, be sure to protect
nished ooring with appropriate material to avoid damage
from moving the appliance.
If the unit has been laid on its back or sides,
place unit upright and allow minimum of 24 hours before
connecng the unit. Failure to do so can aect the funcon and
performance of the appliance.
This appliance should be installed in dry,
venlated indoor locaon. The ambient temperature of the
locaon must be between 55°F (13°C) and 100°F (43°C) for
opmal performance.
This product must be installed on a level
oor for safety and opmal performance. The base must be
at to ensure an-p brackets properly funcon and that
the refrigeraon system is level. Any walls and surrounding
furniture/xtures need to be securely aached to the oor, wall
studs or concrete prior to installaon of the column.
To ensure proper performance, the air
intake (toe kick) must not be blocked. Perlick refrigeraon is
front-breathing — covering the intake will cause the system to
overheat and fail.
Perlick column doors open to 105°. When
installing a panel thicker than ¾” (19), or if located next to
adjacent wall, the 90° hinge stop pin may be required to
prevent damage to the unit and adjacent cabinetry/walls. This
hinge pin must be installed prior to full integraon.
In addion, the appliance must not be in direct exposure of
constant sunlight or excessive heat. If it must be installed next
to a heat source, such as a cooking appliance or radiant heat,
you must install an insulang plate between the column and
heat source.
When fully stocked, Perlick column refrigeraon is very heavy.
To ensure the safety and prevent home damage, the load-
bearing capacity of your oor must be 846 lbs (384 kg).
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
CAUTION
INSTALLATION TOOLS AND MATERIALS
▪ Screwdrivers (standard and #2 Phillips)
▪ Power drill
▪ Drill bits
▪ 13mm socket or wrench set
▪ 2’ and 4’ levels
▪ Material to protect ooring and surrounding cabinetry
OPENING DIMENSIONS - SINGLE UNIT
The depth of each Perlick column is 24” (610). Allow for
panel thickness when planning the nished opening depth. A
minimum of a 4” (102) nished return is required on all sides
of the opening. See page 5 for niche and product dimension
drawings.
It is important that the side walls of the niche are plumb prior
to installaon. The minimum thickness of both the side walls
and the top wall must be 5/8” (16). A thickness of 3/4” (19) is
recommended for toe kick panels.
Framed cabinets will require addional nished ller material
behind the face frame for a proper installaon. Refer to the
illustraon on page 5.
OPENING DIMENSIONS - TWO UNITS
When installing two units side-by-side, a Perlick Dual Installaon
Kit (part number CR-ACC-D1) is required. You must plan for
both units plus dual installaon kit when planning the cut-out
dimensions. ThecutoutwidthforadualCR24installaonis
48”.Thecutoutwidthforadualinstallaonconsisngof
oneCR24andoneCR30is54-1/2”. For more informaon, see
instrucons that accompany the CR-ACC-D1.
CAUTION

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 5
NICHE / PRODUCT DIMENSIONS
A
B
A
A
CR24 24” (610)
CR30 30” (762)
B
CR24 23 -3/4” (604)
CR30 29-3/4” (756)
PLEASENOTE: When installing column adjacent
to wall, a 2” clearance is required if door is opening
towards the wall

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
6 | perlick.com/residential
ELECTRICAL
Serious electroculon hazard. Electrical
grounding is required. This appliance is equipped with a
3-prong (grounding) polarizing plug for your protecon against
possible shock hazards. Failure to comply with these electrical
guidelines may result in possible death or serious injury, re or
loss of property.
Never use an extension cord to connect unit
to electrical source. Do not use a two-prong adapter or remove
the power cord grounding prong.
Installaon must comply with all applicable electrical codes.
The electrical supply must be located within the shaded area
of the illustraon below. A separate circuit, servicing only this
appliance, is required. A ground fault circuit interrupter (GFCI)
is not recommended and may cause interrupon of operaon.
The outlet should be placed in the hatched area dimensioned
below.
Electrical Supply 115V, 60 Hz., Phase 2, 3.3 amps
Service Dedicated 15 amp circuit
Power/Cord Type/ Length NEMA 5-15P w/5’ power cord
WARNING
DANGER
!
ANTI-TIP BRACKET
To prevent the unit from pping forward,
the an-p bracket must be installed. Use all an-p bracket
hardware as instructed. Level as instructed on page 7 prior to
installing an-p bracket(s)
The an-p bracket and supporng hardware is included with
your unit. Please note that four an-p brackets are required
for each unit or dual installaon. In the case of dual installaon,
each individual unit must be ouied with the two an-p
brackets on cabinet sides for a total of four.
For drawings of the an-p bracket installaon on integrated
(built-in) units, see page 8. For drawings of the an-p bracket
installaon on freestanding units, see page 9.
Verify there are no electrical wires or
plumbing in the area which the screws could penetrate.
Always wear safety glasses and use other
necessary protecve devices or apparel when installing or
working with anchors. Anchors are not recommended for use in
lightweight masonry material such as block or brick, or for use
in new concrete which has not had sucient me to cure. The
use of core drills is not recommended to drill holes for anchors.
90° HINGE STOP
Perlick column doors open to 105°. When installing a panel
thicker than ¾” (19), or if located next to adjacent wall, the 90°
hinge stop pin may be required to prevent damage to the unit
and adjacent cabinetry/walls. This hinge pin must be installed
prior to full integraon.
1. Remove the cabinet hinge trim cover by removing the
three Phillips head fasteners located on the top of the
cabinet. Li the rear of trim cover to lt trim cover to
disengage tab on right and le end of trim cover. Slide
forward to remove.
2. Open cabinet door approximately 45° to 85° to expose hole
under hinge guard. Install hinge pin into hole. Ensure hinge
pin is fully seated to top of hinge to prevent damage to
hinge guard.
3. Reaach the cabinet hinge trim piece. Slide front boom
of hinge trim cover under reed switch. Tilt trim cover to
engage right and le end tab into cabinet. Install the three
fasteners.
WARNING
WARNING
CAUTION
ELECTRICAL / ANTI-TIP BRACKET / PRODUCT PLACEMENT
PLACEMENT
Before moving unit into posion, secure the
door closed and protect any nished ooring.
Use an appliance dolly to move the unit near the opening.
CAUTION

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 7
LEVELING / ALIGNMENT
LEVELING/ALIGNMENT
Move the unit near the opening. Plug the power cord into the
grounded outlet and roll the unit into posion. Push unit into
place.
Front and rear leveling legs can be adjusted from the front once
the unit is posioned. To access leveling adjustment access
holes, remove toe kick grill.
Once the unit is in posion, height adjustment can be made
from the front. Using the hex driver leveling tool, turn clockwise
to raise the unit or counterclockwise to lower. Refer to the
illustraon below.
WARNING
CAUTION
When the unit is properly leveled, door adjustments are less
likely to be needed.
To reduce the possibility of the unit pping
forward, the front leveling legs must be in contact with the
oor.
The refrigerated cabinet should be level for
proper operaon, such as door closing, drawer and shelf slide
operaon.

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
8 | perlick.com/residential
ANTI-TIP BRACKET INSTALLATION FOR INTEGRATED INSTALLATION
NOTE: Do not fasten an-p brackets to
adjacent cabinetry unl the cabinet has been
leveled.

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 9
ANTI-TIP BRACKET INSTALLATION FOR FREESTANDING INSTALLATION
NOTE: Cabinet must be leveled before securing
to wall with an-p bracket.

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
10 | perlick.com/residential
DOOR / SIDE PANEL INFORMATION
Finish sides of surrounding cabinetry — they will be visible
when the door is open. The height of the custom door panel
can extend beyond the typical panel height provided the door
and overlay combined do not exceed 242 lbs (110) .
See page 15 for screw zone for overlay panels. Hatch areas
should provide enough thickness for wood screw and overlay
aachment brackets.
SIDE PANELS
Units that are freestanding or parally built-in need to be
nished with custom panels. Custom panels can be built to
customer specicaons to match surrounding cabinetry.
DOOR PANELS
Perlick column refrigeraon comes ready to accept a customer
supplied overlay door panel and customer supplied handle.
Stainless steel door panels and Perlick handles are also
available, and are sold separately of the unit itself. Stainless
steel panels and handles can be purchased through an
authorized Perlick dealer.
STAINLESS STEEL DOOR PANELS
Stainless steel door panels for solid and glass door models
are available through an authorized Perlick dealer. Panels are
constructed of 304 stainless steel (front) and 430 (back plate)
and have a thickness of 3/4” (19). Always allow for panel
thickness when planning the nished opening depth.
Stainless steel panels come pre-drilled for a Perlick handle.
Please note that the Perlick Pro Handle is included with the
purchase of a stainless steel panel.
CUSTOM OVERLAY DOOR PANEL
Perlick columns come ready to accept customer-supplied door
panel and handle hardware. The thickness of the custom panel
can vary. A minimum 5/8” (16) thick panel is required, but
the thickness can be increased provided it does not exceed
the maximum panel weight is 65 lbs (29). Please note that
the combined door and overlay weight cannot exceed 242 lbs
(110). The depth of each model is 24” (610) without a nished
overlay. Allow for panel thickness when planning the nished
opening depth. Templates for 4” and 6” solid and glass door
models can be found on pages 11-14.
Reveals between panels can vary – 1/8” (3) is the minimum.
When installing a panel thicker than 3/4”
(19), the 90° stop may be required to prevent damage to the
unit and adjacent cabinetry.
As reveals between cabinetry and the unit
decrease, severe nger pinching can occur while the door is
closing.
CAUTION
CAUTION

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 11
CR24 SOLID DOOR TEMPLATE FOR 4” TOE KICK
23
3
4
"
79
7
8
"
12
1
2
"
36
1
2
"
60
1
2
"
3
8
"
3
8
"
3
8
"
(4X)
.136 .500
2
1
16
"
19
5
8
"
2
1
16
"
1
3
4
"
2
1
4
"
7
5
8
"
9
3
8
"
14
3
8
"
16
1
8
"
11
7
8
"
1
11
16
"
(2X)
.136
.250
6
3
4
"
A
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL A
SCALE 1 : 2
OVERLAY MTG CLIP DETAIL
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
C
REVISED CLIP HOLE LOCATIONS AND COND.
AIRFLOW MTG HOLE LOCATIONS
11/8/2017
JMP
B
ADDED CONDENSER DIVIDER HOLES
10/3/2017
JMP
A
RELEASE FOR PRODUCTION
8/25/2017
JMP
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007916.slddrw
04/11/2017
11/08/2017
GJ
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
Ang = ±1.0°
Frac. = ±1/16
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPVD BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007916
1007916-1
COLUMN REFRIGERATOR / FREEZER
DOOR WOOD FASCIA - 4" TOE KICK
SCALE = 1:10
SHEET 1 OF 2
A
WOOD

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
12 | perlick.com/residential
CR30 SOLID DOOR TEMPLATE FOR 4” TOE KICK

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 13
CR24 SOLID DOOR TEMPLATE FOR 6” TOE KICK
23
3
4
"
77
7
8
"
12
1
2
"
36
1
2
"
60
1
2
"
3
8
"
3
8
"
3
8
"
(4X)
.136 .500
2
1
16
"
19
5
8
"
2
1
16
"
7
5
8
"
9
3
8
"
14
3
8
"
16
1
8
"
1
3
4
"
2
1
4
"
(12X)
.188
.250
11
7
8
"
1
3
4
"
4
7
8
"
(2X)
.136
.250
B
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL B
SCALE 1 : 2
OVERLAY MTG CLIP DETAIL
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
C
REVISED CLIP HOLE LOCATIONS AND COND.
AIRFLOW MTG HOLE LOCATIONS
11/8/2017
JMP
B
ADDED CONDENSER DIVIDER HOLES
10/3/2017
JMP
A
RELEASE FOR PRODUCTION
8/25/2017
JMP
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007916.slddrw
04/11/2017
11/08/2017
GJ
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
Ang = ±1.0°
Frac. = ±1/16
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPVD BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007916
1007916-2
COLUMN REFRIGERATOR / FREEZER
DOOR WOOD FASCIA - 6" TOE KICK
SCALE = 1:10
SHEET 2 OF 2
A
WOOD

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
14 | perlick.com/residential
CR30 SOLID DOOR TEMPLATE FOR 6” TOE KICK

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 15
CR24 GLASS DOOR TEMPLATE FOR 4” TOE KICK
7
5
8
"
16
1
8
"
12
1
2
"
3
8
"
36
1
2
"
60
1
2
"
6
5
8
"
60"
CUTOUT
17" CUTOUT
2
1
16
" TYP
19
5
8
" TYP
1
3
4
"
3
4
"
FOR LOCK OPTIONAL
USE DRILL FIXTURE TO
LOCATE HOLE
23
3
4
"
79
7
8
"
3
3
8
"
.136
.500 (4X)
3
8
"
3
8
"
2
1
4
"
14
3
8
"
9
3
8
"
11
7
8
"
.136
.500 (2X)
1
11
16
"
6
3
4
"
A
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL A
SCALE 1 : 2
OVERLAY CLIP MTG HOLES
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
F
REVISED MTG HOLE LOCATIONS AND COND. AIRFLOW
DIVIDER MTG HOLES
11/8/2017
JMP
E
UPDATED CLIP MTG HOLE LOCATIONS
10/6/2017
JMP
D
REVISED WINDOW SIZE BY INCREASE CUTOUT WIDTH AND
HEIGHT BY 1-1/4" OVERALL
10/5/2017
JMP
C
ADDED HOLES FOR CONDENSER AIR DIVIDER
10/3/2017
JMP
B
UPDATED HOLE PATTERN FOR ADJUSTMENT BRKT
8/25/2017
JMP
A
INITIAL RELEASE
11/8/2016
TEC
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw
11/28/2016
11/08/2017
JMP
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPROVED BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007917
1007917
FOR COLUMN WINE
OVERLAY, WOOD, 4'' TOE KICK
SCALE = 1:10
SHEET 1 OF 4
A
WOOD

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
16 | perlick.com/residential
CR24 GLASS DOOR TEMPLATE FOR 6” TOE KICK
7
5
8
"
16
1
8
"
12
1
2
"
3
8
"
36
1
2
"
60
1
2
"
6
5
8
"
60"
CUTOUT
17" CUTOUT
2
1
16
" TYP
19
5
8
" TYP
1
3
4
"
3
4
"
FOR LOCK OPTIONAL
USE DRILL FIXTURE TO
LOCATE HOLE
23
3
4
"
77
7
8
"
3
3
8
"
.136
.500 (12X)
.136
.500 (4X)
3
8
"
3
8
"
2
1
4
"
9
3
8
"
14
3
8
"
1
3
4
"
11
7
8
"
.136
.500 (2X)
4
7
8
"
A
3
4
"
1
8
"
1/2" (6X)
3
16
"
1/2" (6X)
DETAIL
A
SCALE
1 : 2
OVERLAY CLIP MTG HOLES
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
F
REVISED MTG HOLE LOCATIONS AND COND. AIRFLOW
DIVIDER MTG HOLES
11/8/2017
JMP
E
UPDATED CLIP MTG HOLE LOCATIONS
10/6/2017
JMP
D
REVISED WINDOW SIZE BY INCREASE CUTOUT WIDTH AND
HEIGHT BY 1-1/4" OVERALL
10/5/2017
JMP
C
ADDED HOLES FOR CONDENSER AIR DIVIDER
10/3/2017
JMP
B
UPDATED HOLE PATTERN FOR ADJUSTMENT BRKT
8/25/2017
JMP
A
INITIAL RELEASE
11/8/2016
TEC
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw
11/28/2016
11/08/2017
JMP
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
Ang = ±1.0°
Frac. = ±1/16
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPROVED BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007917
1007917
FOR COLUMN WINE
OVERLAY, WOOD, 6'' TOE KICK
SCALE = 1:10
SHEET 2 OF 4
A
WOOD

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 17
SCREW ZONE FOR CR24 AND CR30 OVERLAY TEMPLATES
3
1
16
"
3
1
16
"
3
1
4
"
23
3
4
"
66"
3"
69
1
2
"
1"
11
3
8
"
C
L
3
4
"
NOTE:
HATCH AREAS SHOULD PROVIDE ENOUGH
THICKNESS FOR WOOD SCREW FOR
OVERLAY ATTACHMENT BRACKETS.
REV.
DESCRIPTION
DATE
APPROVED
REVISIONS
F
REVISED MTG HOLE LOCATIONS AND COND. AIRFLOW
DIVIDER MTG HOLES
11/8/2017
JMP
E
UPDATED CLIP MTG HOLE LOCATIONS
10/6/2017
JMP
D
REVISED WINDOW SIZE BY INCREASE CUTOUT WIDTH AND
HEIGHT BY 1-1/4" OVERALL
10/5/2017
JMP
C
ADDED HOLES FOR CONDENSER AIR DIVIDER
10/3/2017
JMP
B
UPDATED HOLE PATTERN FOR ADJUSTMENT BRKT
8/25/2017
JMP
A
INITIAL RELEASE
11/8/2016
TEC
2
2
B
A
3
C
B
1
C
1
3
SW
C:\Perlick\Engineering\Projects\Refrigeration\1601802\CAD Files\1007917.slddrw
11/28/2016
11/08/2017
JMP
JMP
-
DIMENSIONS ARE IN INCHES TOLERANCES:
THIS DOCUMENT / PUBLICATION / SOFTWARE / DRAWING CONTAINS PROPRIETARY INFORMATION WHICH IS THE PROPERTY OF THE PERLICK CORPORATION. IT MAY NOT BE REPRODUCED OR TRANSMITTED IN ANY
FORM, ELECTRONIC OR MECHANICAL, INCLUDING PHOTOCOPYING, RECORDING, OR USED IN ANY INFORMATION STORAGE, TRANSMISSION, OR RETRIEVAL SYSTEM, WITHOUT WRITTEN PERMISSION FROM THE PERLICK
CORPORATION. COPYRIGHT 2015 PERLICK CORPORATION. ALL RIGHTS RESERVED.
DRAWN BY:
APPROVED BY:
FINISH:
QTY.:
HOLES:
.0135 THRU
.125:
.004
.1260 THRU
.250:
.005
.2510 THRU
.500:
.006
.5010 THRU
.750:
.008
.7510 THRU
1.000:
.010
1.001 & UP:
.012
BREAK SHARP EDGES - .015 X 45°
RADIUS SHARP FILLETS - .015 TO .031
UNLESS OTHERWISE SPECIFIED:
MATERIAL:
DATE
SIGNATURES
Milwaukee, Wisconsin
Perlick Corporation
DWG NO.
REFERENCE:
PART NO.
PURCHASE REC.:
TITLE:
1007917
1007917
FOR COLUMN WINE
OVERLAY, WOOD, 4'' TOE KICK
SCALE = 1:10
SHEET 3 OF 4
A
WOOD
NOTE:HATCHAREASSHOULD
PROVIDEENOUGHTHICKNESS
FORWOODSCREWSFOROVERLAY
ATTACHMENTBRACKET.
A
CR24 23-3/4”
CR30 29-3/4”
B
CR24 11-3/8”
CR30 14-3/8”
A
B

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
18 | perlick.com/residential
DOOR PANEL INSTALLATION
Typical panel dimensions are based on 84” (2134) nished
height with 1/8” (3) reveals. Template must be adjusted for
panels exceeding typical dimensions.
Place panel face down on a protected work surface. Aach
six clips to the back of overlay in locaons indicated in wood
overlay drawing below.
Use provided #10 x 1/2” screws to aach clips to overlay.
Overlay then slides onto door face. Aach overlay to door
adjustment brackets using remaining #10 x 1/2” screws. Once
mounted, adjust overlay to match adjacent cabinetry.
INSTALLING DOOR OVERLAY PANELS
DOOR OVERLAY PANEL ADJUSTMENT
Close the door to make adjustments to align panels and reveals.
For up and down adjustments, turn the height adjustment
screws in the top bracket (see Top of Door illustraon on page
17) in and out. Adjust the screws as needed to achieve an even
reveal on each side of the door overlay.
Once nal adjustments are made to the posion of the door
overlay, secure the overlay in place by installing the boom
overlay brackets as shown in Boom of Door illustraon below.
BOTTOM OF DOOR

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 19
TOP OF DOOR ILLUSTRATION

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
20 | perlick.com/residential
AIRFLOW DIVIDER
Perlick includes air ow dividers for both 4” and 6” toe kick
installaons. This frame and gasket is installed to the back of
the door panel.
• For 4” toe kick installaons, use part number 1010689-1
• For 6” toe kick installaons, use part number 1010689-2
See instrucons included with airow divider for installaon
informaon.
DOOR TRIM INSTALLATION
DOOR TRIM INSTALLATION
Once overlay is adjusted, mount the door trim bracket onto the
door adjustment bracket using the provided screws.

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 21
COMPLETION - GRILL INSTALLATION
GRILL INSTALLATION
Install the grill by snapping into latch catches.

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
22 | perlick.com/residential
TOE KICK CLEARANCE

PERLICK RESIDENTIAL COLUMN REFRIGERATION INSTALLATION INSTRUCTIONS
perlick customer service (800)558-5592 | 23
INSTALLING FILTERS
CARBON AIR FILTERS
Carbon air lters should be placed in the holder in the
perforated panel located in the top-rear of the cabinet (A).
NOTE: When installing carbon air lter in wine units, the top
rack will need to be removed to access the perforated panel.
1. Remove the lter from the plasc bag before installing into
the unit. Take care not to open or puncture the tyvek bag in the
casing.
2. Pull rmly to lower the carbon air lter panel.
3. Place the carbon air lter into the holder directly onto the
panel and close panel - push rmly to engage closure clips.
4. It is recommended to replace the carbon air lter every 3-6
months.
B
ETHYLENE FILTERS
Ethylene lters should be placed in the holder in top of the p-
out produce bin (B).
1. Remove the lter from the plasc bag before installing into
the unit. Take care not to open or puncture the tyvek bag in the
casing.
2. Open the p-out bin to access lter housing located on the
top of the bin.
3. Slide lter into housing and close p-out bin.
4. It is recommended to replace the ethylene lter every 3
months.

FORM NO. Z2496
REV. D-05/23/2019
8300 West Good Hope Road, Milwaukee, WI 53223, USA
perlick.com/residenal • (800) 558-5592
Perlick Residential is a division of Perlick Corporation
© 2019 Perlick Corporation