installation
5.7 air cooled chimney installation
A. Remove the knock out.
B. Cut away the insulation to gain access to the ring.
C. Remove the ring secured by four screws.
D. Slide the starter collar through the insulation wrap and
affi x using the four screws removed in step C.
E. Secure the inner liner of the chimney to the appliance 8"
(203mm) collar using 3 screws supplied with the starter
collar (W170-0098).
F. Follow the chimney manufacturer's instructions for
installing the chimney.
Use only the following brand and type of chimney.
CHIMNEY COMPONENTS FMI 8DM
12" (304.8mm) Chimney Section 12-8DM
18" (457.2mm) Chimney Section 18-8DM
24" (609.6mm) Chimney Section 24-8DM
36" (914.4mm) Chimney Section 36-8DM
48" (1219.2mm) Chimney Section 48-8DM
Offsets 30E-8DM
Flashing 6F8 or 12F8
Chimney Cap RTL-8HT
Roof Support 38 RS
Firestop FS-8DM
CHIMNEY COMPONENTS WOLF STEEL
Starter Collar NZAC-KT