Loading ...
Loading ...
Loading ...
Page 14
Installation and Operation Manual - Escape 1200
ENGLISH
3.1.2 With Lowered Ceiling
APPLIANCE CLEARANCES WITH SINGLE
WALL PIPE CONNECTOR
Canada USA
A 14" (356 mm) 14" (356 mm)
B 20" (508 mm) 20" (508 mm)
C 11" (279 mm) 11" (279 mm)
L 72" (1829 mm) 72" (1829 mm)
Ve
Ho
L
APPLIANCE CLEARANCES WITH DOUBLE
WALL PIPE CONNECTOR
Canada USA
A 6" (152 mm) 6" (152 mm)
B 18" (457 mm) 18" (457 mm)
C 8" (203 mm) 8" (203 mm)
L 72" (1829 mm) 72" (1829 mm)
If the above clearances are met, then the distances measured from the flue outlet will be:
DISTANCES
17
FROM PIPE CONNECTOR
WITH SINGLE WALL PIPE CONNECTOR
DISTANCES
17
FROM PIPE CONNECTOR
WITH DOUBLE WALL PIPE CONNECTOR
Canada USA Canada USA
D
18" (457 mm) 18" (457 mm)
D
9 ¼" (235 mm) 9 ¼" (235 mm)
E
26 ½" (673 mm) 26 ½" (673 mm)
E
23 ¾" (603 mm) 23 ¾" (603 mm)
F
18 ¼" (464 mm) 18 ¼" (464 mm)
F
14 ½" (368 mm) 14 ½" (368 mm)
17
The pipe distances listed in this table refer to the distances obtained when the stove is installed in accordance with the appliance clearances
above mentioned.
Loading ...
Loading ...
Loading ...