APPLICATIONS
ROOM AIR CONDITIONER/HEAT PUMP
OceanAire ArcticAire and ConvertibleAire units can be used as a room air conditioner to cool the
entire enclosed space. In this application, condenser hot exhaust air venting and condenser air
intake ducting is required. Use the optional "Flexible Duct" and the "Condenser Inlet Air
Plenum" as specified in the optional features section. ConvertibleAire units can be used to heat a
space to a desired temperature, but, not warmer than 85° F. If a condenser inlet air plenum is not
used, negative pressure created in the space by the condenser blower may cause a net temperature
increase in the room. Please consult your Oceanaire distributor or factory for assistance.
SPOT COOLER/HEATER
ArcticAire/ConvertibleAire units can be used in an open environment to cool specific objects or
"spots" through the evaporator grille, the optional nozzles or the optional duct adapter. Spot
Cooling is a convenient and economical way to provide air conditioning where cooling the entire
space is impractical. In this application, ducts for condenser air intake and hot air exhaust are not
often not required. If heating cool spots are required, ConvertibleAire units may be used in the
“heating” mode.
AREA COOLER/HEATER
When ArcticAire or ConvertibleAire is installed in an area that is not totally enclosed, the
(optional) condenser hot air exhaust duct directs condenser air out of the area, allowing the
evaporator air to cool the specific space.
INSTALLATION INSTRUCTIONS
BEFORE INSTALLING: Check the air conditioner/spot cooler for any damage. Air conditioners
are thoroughly inspected at the factory and carefully packaged. If any damage is evident, file a
claim with the delivering carrier immediately.
ELECTRICAL REQUIREMENTS: Check the data plate on the back of the unit to make certain
that the proper power is available. Refer to "Specifications" section for voltage and fuse/circuit
breaker requirement. For proper NEMA receptacles, refer to "Electrical service plug
configuration". Operating the unit on improper voltage will void the warranty. Caution: An
extension cord can be used provided it is rated at least 20 amps@ 120 volts, or 20 amps@ 250
volts with grounding-type attachment plug and grounding type connector (load fitting). For
Models 2OAC/2OACH6012 at least 50 amps@ 250 volts and for Models 2OAC/2OACH6032 at
least 30 amps@ 250 volts 3 phase.
OceanAire ArcticAire/ConvertibleAire portable air conditioner/spot cooler/heater requires
minimal installation. Plug unit in proper NEMA receptacle and it immediately begins to cool or
heat. The entire system is built into one compact unit which can be moved and installed with
ease.
DO NOT INSTALL UNIT AGAINST A WALL. A MINIMUM OF 8 INCHES OF
CLEARANCE IS REQUIRED BETWEEN THE WALL AND THE BACK OF THE
UNIT.