Typical CFM Vs. Static Pressure “WC
1.0” 1.5” 2.0” 2.5” 3.0” 3.5” 4.0”
GP301c 64 54 41 4 - - -
GP501c - - 66 58 50 27 4
Model Size Weight Inlet/Outlet
GP301c 13”H x 12.5” Dia. 12 lbs 3.5” OD
GP501c 13”H x 12.5” Dia. 12 lbs 3.5” OD
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
GP301c 56-100 watts 2.3” WC
GP501c 68 - 146 watts 3.8” WC
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
GPc Series Product Specications
Typical CFM Vs. Static Pressure “WC
Model 0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0”
RP140c 135 103 70 14 - - - -
RP145c 166 146 126 104 82 61 41 21 3
RP260c 251 209 157 117 70 26 - - -
RP265c 334 291 247 210 176 142 116 87 52
Model Recommended Duct PVC Pipe Mounting Thermal Cutout Insulation Class
RP140c
3” or 4” Schedule
20/40 PVC
Mount on the duct pipe or with
optional mounting bracket.
For Ventilation: 4”, 6” or 8” Rigid
or Flexible Ducting.
130
o
C/266
o
F Class B Insulation
RP145c 130
o
C/266
o
F
Class F InsulationRP260c 150
o
C/302
o
F
RP265c 150
o
C/302
o
F
XP201c
3” or 4” Schedule
20/40 PVC
Fan may be mounted on the duct
pipe or with integral anges.
120
o
C/248
o
F Class B Insulation
XR261
GP301c
3” or 4” Schedule
20/40 PVC
Fan may be mounted on the duct
pipe or with integral anges.
120
o
C/248
o
F Class B Insulation
GP501c
RPc, XPc, XR and GPc Series Additional Specications
Continuous Duty
3000 RPM
Thermally Protected
RPc, GPc Residential and Commercial
XPc, XR Residential Only
Rated for Indoor or Outdoor Use
Loading ...