RadonAway RP265C RP265 Radon Mitigation Fan

User Manual - Page 6

For RP265C. Also, The document are for others RadonAway models: RP140C, RP145C, RP260C

PDF File Manual, 8 pages, Read Online | Download pdf file

RP265C photo
Loading ...
Loading ...
Loading ...
IN096 Rev A 0718 63 Saber Way Ward, Hill, MA 01835 | radonaway.com
Typical CFM Vs. Static Pressure “WC
0” .5” 1.0” 1.5” 1.75” 2.0”
XP201c 112 95 70 40 - -
XR261 217 149 87 27 - -
Model Size Weight Inlet/Outlet
XP201c 9.5”H x 8.5” Dia. 6 lbs 4.5” OD
XR261 9.5”H x 8.5” Dia. 7 lbs 6” OD
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
XP201c 45 - 66 watts 1.7” WC
XR261 67 - 117 watts 1.6” WC
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
THE FOLLOWING CHARTS SHOW THE PERFORMANCE OF THE RPc, GPc, XPc and XR SERIES FANS
XPc and XR Series Product Specications
Typical CFM Vs. Static Pressure “WC
Model 0” .25” .5” .75” 1.0” 1.25” 1.5” 1.75” 2.0”
RP140c 135 103 70 14 - - - -
RP145c 166 146 126 104 82 61 41 21 3
RP260c 251 209 157 117 70 26 - - -
RP265c 334 291 247 210 176 142 116 87 52
Model Size Weight Inlet/Outlet L.2
RP140c 8.5”H x 9.7” Dia. 5.5 lbs 4.5”OD (4.0” PVC Sched 40 size compatible) 25
RP145c 8.5”H x 9.7” Dia. 5.5 lbs 4,5” OD 15
RP260c 8.6”H x 11.75” Dia. 5.5 lbs 6.0” OD 48
RP265c 8.6”H x 11.75” Dia. 6.5 lbs 6.0” OD 30
Model
Power Consumption
120VAC, 60Hz, 1.5 Amp Maximum
Maximum Recommended Operation Pressure*
(Sea Level Operation)**
RP140c 15 - 21 watts 0.7” WC
RP145c 41 - 72 watts 1.7” WC
RP260c 47-65 watts 1.3” WC
RP265c 91-129 watts 2.2” WC
L.2 = Estimated Equivalent Length of Rigid Metal Ducting resulting in .2” WC pressure loss for Duct Size listed. Longer Equivalent Lengths
can be accommodated at Flows Lower than that at .2” WC pressure loss (see CFM Vs Static Pressure “WC Table).
*Reduce by 10% for High Temperature Operation **Reduce by 4% per 1000 ft. of altitude.
RPc Series Product Specications
Loading ...
Loading ...