Dyna Glo EG10000DG 10,000W 240V Forced Air Electric Garage Heater

User Manual - Page 8

For EG10000DG.

PDF File Manual, 48 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
8
CONNECTING THE POWER
If you will use an external temperature control (external thermostat) to control the
heater to be operated or not, please follow below attention points:
1.Makesurethattheheater'stemperaturecontrolknob(thermostatknob)isturnedfully
clockwise.
2.Connectthewireaccordingtobelowwiringdiagram.
NOTE:
The heater equipped with a single-phase
power supply, using a three-phase power
supply, the L1 (red wire) and L3 (blue wire)
(see gure 1) must be connected to the L2
(see gure 2).
INSTALLATION
Selection Switch
(Heater’s thermostat, External thermostat)
Heater’s
thermostat
External
thermostat
Figure 1
Figure 2
HeaterRating
&Voltage
HeaterAmps
MaxFuse
Size
Min.WireSize
75c Copper
Singlephase
10kw@240V
41.7 60 #6
Three-phase
10kw@240V
26 38 #10
Loading ...
Loading ...
Loading ...