Storage
If you are not going to use the humidier for a long time, make sure that all its parts
are dry, including the operating chamber of the sprayer.
Do not store the unit with water in the water tank and in the operating chamber of
the sprayer.
Clean and dry the lter-cartridge before taking it away for storage. Keep the lter-
cartridge in a cool darkened place.
Keep the humidier away from children in a dry cool place.
TROUBLESHOOTING
Problem Possible Cause Suggested Solution
Power lamp off or does
not work
Humidier is not plugged
into the power outlet or
loose.
Connect power cord to
electrical outlet and press
power button
Power lamp is on but no
mist
No water in water tank Fill water into water tank
The mist has a strange
odour
A New unit Take out water tank, open
cover, let it stay 12 hours
in cool position
It either has dirty water
or the water has been
stagnant too long
Clean water tank, ll with
clear water
Power light is on, but the
machine doesn’t work.
Too much water in the
water basin
Remove the water tank.
Take a small cup and
remove some of the water
from the machine’s water
basin. Reinsert the water
tank and make sure that it
sits properly