Loading ...
Loading ...
Loading ...
Installat
ion and User Instructions R01127
-9 09/15
Page
28
Technical Data
Direct Electric Cylinder Range - Dimensions
Reference
125
150
210
250
300
Weight [kg]
23
26
33
39
46
Reheat time [mins]*
122
150
218
284
313
Heat Loss [kWh]
0.95
1.10
1.41
1.51
1.96
Height [mm]
945
1115
1490
1765
2065
Outer Diameter [mm]
580
580
580
580
580
HW Outlet [mm]
720
890
1265
1540
1840
T&P valve [mm]
720
890
1265
1540
1840
CW Inlet [mm]
180
180
180
180
180
Bottom Immersion [mm]
200
200
200
200
200
Top Immersion [mm]
560
695
1070
1345
1645
Table 5: Direct Electric Cylinder Product Dimensions
Note: All measurements are taken from the base of the cylinder to the mid-point on the item.
* Determined in accordance with EN160335-2-21.
Table 6: Direct Electric Cylinder Product Fiche
GDC Group Ltd
Direct Electric Cylinder Range Product Fiche
Reference
ECSd125-
580
ECSd150-
580
ECSd210-
580
ECSd250-
580
ECSd300-
580
Load Profile Primary
M
M
M
L
L
Energy Rating
C
C
C
C
C
Energy Efficiency
36%
37%
36%
37%
37%
Annual Energy
Consumption
1411
1389
1435
2739
2774
Load Profile
Secondary
-
-
-
M
M
Set Temperature
60°C
60°C
60°C
60°C
60°C
Sound Level [dB]
15dB
15dB
15dB
15dB
15dB
Operating Mode
Off Peak
Off Peak
Off Peak
Off Peak
Off Peak
V-40
204
242
355
415
490
Loading ...
Loading ...
Loading ...