Installation
5.2 Hot Water Outlet
The hot water pipe work is to be
directly connected to the hot water
outlet connection on the cylinder, see
Figure 1.
5.2.1 Thermostatic mixing
valve
A thermostatic mixing valve may be
required to limit the outlet
temperature. In this case, the valve
should be installed following the
manufacturers instructions, ensuring
none of the safety equipment has
been isolated, (i.e. make sure the
connection to the thermostatic mixing
valve is taken after the safety
equipment of the inlet group).
5.2.2 Pipe insulation
It is recommended to insulate the hot
water pipe work from the cylinder to
the outlets, to reduce the energy
requirements for providing hot water.
It is also recommended to insulate all
other exposed pipework, such as the
T&P to the tundish, the coil flow and
return and the cold water inlet pipes.
5.3 Discharge pipes from
safety devices
5.3.1 Discharge pipe D1
- The temperature and pressure relief
valve must be discharged directly or
by way of a manifold via a short
length of metal pipe (D1) into a
tundish; and the discharge pipe
must be installed in a continuously
downward direction and in a frost
free environment. Water may drip
from the discharge pipe of the
pressure relief device and this pipe
must be left open to the
atmosphere.
- The diameter of discharge pipe (D1)
should not be less than the nominal
outlet size of the safety device, e.g.
temperature relief valve.
- Where a manifold is used it should
be sized to accept and discharge
the total discharge from all the D1
discharge pipes connected to it.
- The discharge pipe work from the
expansion relief valve must be
installed constantly falling to an
open point of discharge. It is
recommended to combine it with
the discharge of the temperature
and pressure relief valve.
Note: The T&P valve is pre-sealed
and if moved the seal will be
broken, should this occur, it will
need to be resealed with an
appropriate sealant (Dimplex part
number R00836-1).
5.3.2 Discharge pipe D2
For a detailed description of the
discharge pipework D2 see chapter
4.4.1.