Dyna Glo RMC-FA125DGD Dyna-Glo Delux 125,000 BTU Portable Forced Air Propane Heater

User Manual - Page 4

For RMC-FA125DGD.

PDF File Manual, 22 pages, Read Online | Download pdf file

RMC-FA125DGD photo
Loading ...
Loading ...
Loading ...
The heater is designed and approved for use as a construction heater under ANS Z83.7 CSA 2.14. It is hard
to anticipate every use which may be made of this heater. CHECK WITH YOUR LOCAL FIRE SAFETY
AUTHORITY IF YOU HAVE QUESTIONS ABOUT APPLICATIONS.
DYNA-GLO PROPANE FORCED AIR CONSTRUCTION HEATERS
This is a direct-red forced air construction heater for either indoor construction or outdoor use. Its intended
use is primarily the temporary heating of buildings or structures under construction, alteration or repair. All the
products of combustion generated by the heater are forced through the heater and released into the area being
heated. This heater operates at approximately 98%+ combustion efciency but still produces a small amount
of carbon monoxide. Humans can tolerate small amounts of carbon monoxide for short periods. Carbon
monoxide can build up in a heated space and failure to provide adequate ventilation could result in poisoning
or death.
PROPANE CONSTRUCTION HEATER
3 4
Other standards govern the use of fuel gases and heat producing products in specic applications.
Your local authority can advise you about these.
IMPORTANT: READ THIS USER’S MANUAL CAREFULLY AND COMPLETELY BEFORE TRYING
TO OPERATE OR SERVICE THIS HEATER. IMPROPER USE OF THIS HEATER CAN CAUSE
SERIOUS INJURY OR DEATH FROM FIRE, EXPLOSION AND CARBON MONOXIDE POISONING.
SPECIFICATIONS
WARNING
: NOT FOR USE WITH DUCT WORK.
RMCFA40DGP/
DGP01
FA50Series FA60Series
RMCFA100DGD/
DGP/DGP01
LPFA125DGD/
RMCFA125DGP/
DGP01
LPFA125H/H01/
RMCFA125DGD

RMCFA150DGD
40,000BTU/hr
30,000BTU/hr
50,000BTU/hr
30,000BTU/hr
60,000BTU/hr
70,000BTU/hr
100,000BTU/hr
70,000BTU/hr
125,000BTU/hr
70,000BTU/hr
125,000BTU/hr
120,000BTU/hr
150,000BTU/hr
Propane Propane Propane Propane Propane Propane Propane
CylinderPressure CylinderPressure CylinderPressure CylinderPressure CylinderPressure CylinderPressure CylinderPressure
5psig 5psig 5psig 5psig 5psig 5psig 5psig
11"W.C 11"W.C 11"W.C 11"W.C 11"W.C 11"W.C 11"W.C
1.9lbs/hr0.86kg/hr
1.4lbs/hr0.63kg/hr
2.3lbs/hr1.04kg/hr
1.4lbs/hr0.63kg/hr
2.8lbs/hr1.27kg/hr
3.3lbs/hr1.5kg/hr
4.6lbs/hr2.09kg/hr
3.3lbs/hr1.5kg/hr
5.8lbs/hr2.63kg/hr
3.3lbs/hr1.5kg/hr
5.8lbs/hr2.63kg/hr
5.6lbs/hr2.54kg/hr
7.0lbs/hr3,18kg/hr
120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø 120V,60Hz,1Ø
Amperage Load 0.68amps 0.65amps 0.65amps 0.7amps 0.7amps 0.7amps 0.7amps
Fan
Unload
Load
3550rpm
3000rpm
3570rpm
3300rpm
3570rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
3580rpm
3300rpm
Piezo/ManualSpark ContinuousSpark ContinuousSpark ContinuousSpark ContinuousSpark ContinuousSpark ContinuousSpark
0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.16"(4mm) 0.11"(2.8mm)
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
19.3"x8.3"x15.2"
(49.0x21.1x38.6)cm
25.6"x12.7"x15.6"
(65.0x32.3x39.6)cm
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
26.6"x13.0"x17.3"
(67.6x33.0x43.9)cm
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
26.2"x11.8"x17.2"
(66.6x30.0x43.6)cm
25.6"x11.8"x16.1"
(65.0x30.0x41.0)cm
25.6"x11.8"x16.1"
(65.0x30.0x40.9)cm
Size(LxWxH)
ManifoldPressure
GasConsumption
ElectricalInput
Ignition
SparkGap
ModelNo.
InputRating
TypeofGas
GasSupplyPressureto
RegulatorMaximum
Minimum(forpurposeof
InputAdjustment)
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Loading ...
Loading ...
Loading ...