9 10
PROPANE CONSTRUCTION HEATER
SHUTDOWN INSTRUCTIONS
TEST FIRING HEATER
Test re your construction heater, following the lighting instructions applicable to the gas control sys-
tem employed. Leak test all gas connections with soap solution. Soap bubbles indicate gas leakage.
DO NOT use a match or ame to test for gas leaks.
STORAGE
Never store a Propane gas tank inside a building or in the vicinity of any gas or oil burning appliance.
When the Propane tank is not disconnected from the construction heater, the gas tank and heater
must be stored outdoors in a well ventilated area, out of the reach of children. If for any reason the
heater is to be stored indoors, the tank must be disconnected and stored outdoors in a well ventilated
area out of reach of children, in accordance with the standard for the the Storage and Handling of
Liqueed Petroleum Gases, ANSI / NFPA 58 and CSA B149.1, Natural Gas and Propane Installation
Code. The plastic tank valve plug supplied with your tank must be tightly installed when the tank is
disconnected from the heater.
MAINTENANCE INSTRUCTIONS
1. Turn unit off, allow heater to fully cool and disconnect propane hose before performing any Mainte-
nance
functions. Unplug the unit from the 120V receptacle.
2. Keep unit clean and keep the inside of the torpedo housing debris free.
3. Have unit checked by a qualied technician at least once a year, preferably prior to the heating
season.
WARNING
: Motor and fan must be running before lighting, during operation and at shutdown,
in order to prevent a ame-out condition which could result in personal injury or property damage.
Turn gas valve knob clockwise to OFF position.
Turn gas supply OFF by turning Propane tank valve clockwise to close.
Disconnect the power cord once the heater has cooled to ambient temperature.
REPLACEMENT PARTS
Warning: Use only original replacement
parts. This Heater must use design-specic
parts. Do not substitute or use generic parts.
Improper replacement parts could cause
serious or fatal injuries.
This will also protect your warranty coverage
for parts replaced under warranty.
Parts warranty and non-warranty: Contact
authorized dealers of this product. If they can
not supply original replacement part(s), either
contact your nearest Parts Central or GHP
Group Inc., Technical Service Department at
1-877-447-4768.
When calling GHP Group Inc., have ready:
• your name
• your address
• how heater was malfunctioning
• serial number of heater
• model number of heater
• replacement part number
NEVER LEAVE THE HEATER
UNATTENDED WHILE BURNING!
Loading ...