Napoleon GVFL30P Fiberglow VF30

User Manual - Page 11

For GVFL30P.

PDF File Manual, 28 pages, Read Online | Download pdf file

GVFL30P photo
Loading ...
Loading ...
Loading ...
EN
W415-0809 / D / 02.26.21
11
installation
MINIMUM DAMPER OPENING
(SQUARE INCHES)
CHIMNEY
HEIGHT
MASONRY
APPLIANCE
FACTORY BUILT
APPLIANCE
6
33.8”
8
31.2”
10
28.7” 22.1”
15
26.1” 17.3”
20
23.7” 14.5”
25
22.7” 12.6”
30
21.6” 11.3”
35
10.8”
40
10.2”
Use the 3” adjustable bolt to adjust the damper to the
correct opening, based on the enclosed chart.
Should the damper stop not fit, or provide the required
permanent opening from the Minimum Damper
Opening table, have the damper cut to provide a
minimum permanent opening or install an alternate
stop.
Any outside air ducts and/or ash dumps in the
appliance shall be permanently closed at time of
appliance installation.
3.3 gas piping
This appliance and it’s appliance main valve must be disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess of ½ PSI (3.5kPa)
This appliance must be isolated from the gas supply piping system
by closing the individual manual shut off valve during any pressure
testing of the gas supply piping system at test pressure equal to or
less than ½ psi (3.5 kPa)
A. Centre the appliance in the appliance opening, making
sure the appliance has enough room behind it for the gas
line to run behind the log set under the log support.
B. Route the gas line and sizing using piping ½” diameter or
greater to allow the full volume of gas to the appliance.
The routing of the gas line has to be done to local and / or
national codes.
C. When rigid pipe is used an ANSI approved manual shut
off and a union must be installed upstream within the
appliance cavity.
D. To ensure the appliance operates reliably install a sediment
trap upstream of the appliance within the structures of the piping system.
E. When using propane, a regulator must be used between the tank and the outside wall of the house to
ensure the line pressure does not exceed 14” w.c.
F. Check gas connections with a gas detection device to test for leaks in the system. Soapy water mixture
can also be used to check for leaks.
G. Once all the gas connections are tested for leaks, start the appliance. Follow the lighting instructions to
ensure the appliance is working properly before finishing.
Regulator
Union
Manual
Shut-Off
Valve
Wall
Shut-Off
Key
Sediment
Trap
Appliance
Appliance
3" (76.3mm)
!
WARNING
Do not connect either the wall switch, thermostat or gas valve to electricity (110 volts).